hwmon: (lm90) Introduce capability flag to indicate broken ALERT functionality

Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Signed-off-by: Jean Delvare <khali@linux-fr.org>
diff --git a/drivers/hwmon/lm90.c b/drivers/hwmon/lm90.c
index 9df08e1..1913f8a 100644
--- a/drivers/hwmon/lm90.c
+++ b/drivers/hwmon/lm90.c
@@ -162,6 +162,7 @@
 #define LM90_HAVE_EMERGENCY	(1 << 4) /* 3rd upper (emergency) limit	*/
 #define LM90_HAVE_EMERGENCY_ALARM (1 << 5)/* emergency alarm		*/
 #define LM90_HAVE_TEMP3		(1 << 6) /* 3rd temperature sensor	*/
+#define LM90_HAVE_BROKEN_ALERT	(1 << 7) /* Broken alert		*/
 
 /*
  * Driver data (common to all clients)
@@ -200,11 +201,13 @@
 
 static const struct lm90_params lm90_params[] = {
 	[adm1032] = {
-		.flags = LM90_HAVE_OFFSET | LM90_HAVE_REM_LIMIT_EXT,
+		.flags = LM90_HAVE_OFFSET | LM90_HAVE_REM_LIMIT_EXT
+		  | LM90_HAVE_BROKEN_ALERT,
 		.alert_alarms = 0x7c,
 	},
 	[adt7461] = {
-		.flags = LM90_HAVE_OFFSET | LM90_HAVE_REM_LIMIT_EXT,
+		.flags = LM90_HAVE_OFFSET | LM90_HAVE_REM_LIMIT_EXT
+		  | LM90_HAVE_BROKEN_ALERT,
 		.alert_alarms = 0x7c,
 	},
 	[lm86] = {
@@ -1361,7 +1364,7 @@
 		/* Disable ALERT# output, because these chips don't implement
 		  SMBus alert correctly; they should only hold the alert line
 		  low briefly. */
-		if ((data->kind == adm1032 || data->kind == adt7461)
+		if ((data->flags & LM90_HAVE_BROKEN_ALERT)
 		 && (alarms & data->alert_alarms)) {
 			dev_dbg(&client->dev, "Disabling ALERT#\n");
 			lm90_read_reg(client, LM90_REG_R_CONFIG1, &config);