spi/bfin_spi: handle error/status changes after data interrupts
The error interrupt on the BF537 SIC cannot be enabled on a
per-peripheral basis. Once the error interrupt is enabled
for one peripheral, it is automatically enabled for all.
So in the Blackfin on-chip SPI driver, we need to clear out
these known errors in the data interrupt once we've successfully
finished processing all of the pending data.
Signed-off-by: Michael Hennerich <michael.hennerich@analog.com>
Signed-off-by: Mike Frysinger <vapier@gentoo.org>
Signed-off-by: Grant Likely <grant.likely@secretlab.ca>
diff --git a/drivers/spi/spi_bfin5xx.c b/drivers/spi/spi_bfin5xx.c
index ab483a0..d3da41d 100644
--- a/drivers/spi/spi_bfin5xx.c
+++ b/drivers/spi/spi_bfin5xx.c
@@ -504,6 +504,15 @@
"in dma_irq_handler dmastat:0x%x spistat:0x%x\n",
dmastat, spistat);
+ if (drv_data->rx != NULL) {
+ u16 cr = read_CTRL(drv_data);
+ /* discard old RX data and clear RXS */
+ bfin_spi_dummy_read(drv_data);
+ write_CTRL(drv_data, cr & ~BIT_CTL_ENABLE); /* Disable SPI */
+ write_CTRL(drv_data, cr & ~BIT_CTL_TIMOD); /* Restore State */
+ write_STAT(drv_data, BIT_STAT_CLR); /* Clear Status */
+ }
+
clear_dma_irqstat(drv_data->dma_channel);
/*