mwl8k: increase firmware loading timeouts

The time between loading the helper image and starting to upload the
main firmware image should be at least 5 ms or so.  We were doing an
msleep(1) before, and 1 ms appears to not be enough in almost all
cases, but building with HZ=100 has always masked this so far.  Bumping
the msleep argument to 5 fixes firmware loading e.g. when HZ=1000.

Some firmware images need more than 200ms to initialize.  Bump the
ready code timeout to 500ms to accommodate for this.

Signed-off-by: Lennert Buytenhek <buytenh@marvell.com>
Signed-off-by: John W. Linville <linville@tuxdriver.com>
diff --git a/drivers/net/wireless/mwl8k.c b/drivers/net/wireless/mwl8k.c
index a162558..e59a926 100644
--- a/drivers/net/wireless/mwl8k.c
+++ b/drivers/net/wireless/mwl8k.c
@@ -571,7 +571,7 @@
 			       "helper image\n", pci_name(priv->pdev));
 			return rc;
 		}
-		msleep(1);
+		msleep(5);
 
 		rc = mwl8k_feed_fw_image(priv, fw->data, fw->size);
 	} else {
@@ -588,9 +588,8 @@
 		iowrite32(MWL8K_MODE_AP, priv->regs + MWL8K_HIU_GEN_PTR);
 	else
 		iowrite32(MWL8K_MODE_STA, priv->regs + MWL8K_HIU_GEN_PTR);
-	msleep(1);
 
-	loops = 200000;
+	loops = 500000;
 	do {
 		u32 ready_code;