HID: be more strict when ignoring out-of-range fields

HID 1.11 specification, section 5.10 tells us:

	HID class devices support the ability to ignore selected fields in a
	report at run- time. This is accomplished by declaring bit field in a
	report that is capable of containing a range of values larger than
	those actually generated by the control. If the host or the device
	receives an out-of-range value then the current value for the
	respective control will not be modified.

So we shouldn't be restricted to EV_ABS only.

Reported-by: Denilson Figueiredo de Sá <denilsonsa@gmail.com>
Tested-by: Denilson Figueiredo de Sá <denilsonsa@gmail.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
diff --git a/drivers/hid/hid-input.c b/drivers/hid/hid-input.c
index b7b0d55..6e32526 100644
--- a/drivers/hid/hid-input.c
+++ b/drivers/hid/hid-input.c
@@ -822,9 +822,8 @@
 		return;
 	}
 
-	/* Ignore absolute values that are out of bounds */
-	if ((usage->type == EV_ABS && (value < field->logical_minimum ||
-					value > field->logical_maximum))) {
+	/* Ignore out-of-range values as per HID specification, section 5.10 */
+	if (value < field->logical_minimum || value > field->logical_maximum) {
 		dbg_hid("Ignoring out-of-range value %x\n", value);
 		return;
 	}