sfc: Log interrupt and reset type names, not numbers
Define name tables for these enumerations in a similar way as for
loopback. Move the loopback name table together with them.
Signed-off-by: Ben Hutchings <bhutchings@solarflare.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
diff --git a/drivers/net/sfc/selftest.c b/drivers/net/sfc/selftest.c
index afac1cc..63ff295 100644
--- a/drivers/net/sfc/selftest.c
+++ b/drivers/net/sfc/selftest.c
@@ -175,8 +175,8 @@
return -ETIMEDOUT;
success:
- EFX_LOG(efx, "test interrupt (mode %d) seen on CPU%d\n",
- efx->interrupt_mode, efx->last_irq_cpu);
+ EFX_LOG(efx, "%s test interrupt seen on CPU%d\n", INT_MODE(efx),
+ efx->last_irq_cpu);
tests->interrupt = 1;
return 0;
}