PFW: Do not stop on hard sync errors
BZ: 76263
When synchronization fails, the parameter-framework should
log a warning and continue synchronization instead of stopping
Change-Id: Ic12d8798ea25584db714ee26e644fac793c28881
Signed-off-by: Kevin Rocard <kevinx.rocard@intel.com>
Reviewed-on: http://android.intel.com:8080/81825
Reviewed-by: Centelles, Sylvain <sylvain.centelles@intel.com>
Reviewed-by: Denneulin, Guillaume <guillaume.denneulin@intel.com>
Tested-by: Dixon, CharlesX <charlesx.dixon@intel.com>
Reviewed-by: cactus <cactus@intel.com>
Tested-by: cactus <cactus@intel.com>
diff --git a/parameter/ConfigurableElement.cpp b/parameter/ConfigurableElement.cpp
index cde2ee7..2962295 100644
--- a/parameter/ConfigurableElement.cpp
+++ b/parameter/ConfigurableElement.cpp
@@ -458,7 +458,7 @@
{
const CElement* pParent = getParent();
- // Stop at sytem class
+ // Stop at system class
if (!pParent->getParent()) {
return NULL;