commit | 113885e9805ab990061cd1be62e5fc96e0dcece6 | [log] [tgz] |
---|---|---|
author | Ashish Garg <ashigarg@codeaurora.org> | Thu Aug 25 16:42:21 2016 +0530 |
committer | Ashish Garg <ashigarg@codeaurora.org> | Tue Aug 30 18:34:06 2016 +0530 |
tree | 9d1475ab5957b7ef7f0548542a48b1c252c557d0 | |
parent | 49c118e62f1b594b62ac0fbc30832c13787481f8 [diff] |
target: msm8996: correct PLL unlock sequence Turning off the clock source (PLL) prior to turning off the RCGs may leave the RCGs in the bad state (stuck at on). Update the unlock/stop sequence for clocks. Change-Id: I53b430e310995e1ea134688e92e283499d42bf86 Signed-off-by: Ashish Garg <ashigarg@codeaurora.org>