target: msm8996: correct PLL unlock sequence

Turning off the clock source (PLL) prior to turning off the
RCGs may leave the RCGs in the bad state (stuck at on).
Update the unlock/stop sequence for clocks.

Change-Id: I53b430e310995e1ea134688e92e283499d42bf86
Signed-off-by: Ashish Garg <ashigarg@codeaurora.org>
1 file changed