Bluetooth: Fix HCI_RESET command synchronization
We can't send new commands before a cmd_complete for the HCI_RESET command
shows up.
Reported-by: Mikko Vinni <mmvinni@yahoo.com>
Reported-by: Justin P. Mattock <justinmattock@gmail.com>
Reported-by: Ed Tomlinson <edt@aei.ca>
Signed-off-by: Gustavo F. Padovan <padovan@profusion.mobi>
Tested-by: Justin P. Mattock <justinmattock@gmail.com>
Tested-by: Mikko Vinni <mmvinni@yahoo.com>
Tested-by: Ed Tomlinson <edt@aei.ca>
diff --git a/net/bluetooth/hci_event.c b/net/bluetooth/hci_event.c
index 3fbfa50..cebe7588 100644
--- a/net/bluetooth/hci_event.c
+++ b/net/bluetooth/hci_event.c
@@ -183,6 +183,8 @@
BT_DBG("%s status 0x%x", hdev->name, status);
+ clear_bit(HCI_RESET, &hdev->flags);
+
hci_req_complete(hdev, HCI_OP_RESET, status);
}
@@ -1847,7 +1849,7 @@
if (ev->opcode != HCI_OP_NOP)
del_timer(&hdev->cmd_timer);
- if (ev->ncmd) {
+ if (ev->ncmd && !test_bit(HCI_RESET, &hdev->flags)) {
atomic_set(&hdev->cmd_cnt, 1);
if (!skb_queue_empty(&hdev->cmd_q))
tasklet_schedule(&hdev->cmd_task);