Bluetooth: Fix HCI_RESET command synchronization

We can't send new commands before a cmd_complete for the HCI_RESET command
shows up.

Reported-by: Mikko Vinni <mmvinni@yahoo.com>
Reported-by: Justin P. Mattock <justinmattock@gmail.com>
Reported-by: Ed Tomlinson <edt@aei.ca>
Signed-off-by: Gustavo F. Padovan <padovan@profusion.mobi>
Tested-by: Justin P. Mattock <justinmattock@gmail.com>
Tested-by: Mikko Vinni <mmvinni@yahoo.com>
Tested-by: Ed Tomlinson <edt@aei.ca>
diff --git a/net/bluetooth/hci_event.c b/net/bluetooth/hci_event.c
index 3fbfa50..cebe7588 100644
--- a/net/bluetooth/hci_event.c
+++ b/net/bluetooth/hci_event.c
@@ -183,6 +183,8 @@
 
 	BT_DBG("%s status 0x%x", hdev->name, status);
 
+	clear_bit(HCI_RESET, &hdev->flags);
+
 	hci_req_complete(hdev, HCI_OP_RESET, status);
 }
 
@@ -1847,7 +1849,7 @@
 	if (ev->opcode != HCI_OP_NOP)
 		del_timer(&hdev->cmd_timer);
 
-	if (ev->ncmd) {
+	if (ev->ncmd && !test_bit(HCI_RESET, &hdev->flags)) {
 		atomic_set(&hdev->cmd_cnt, 1);
 		if (!skb_queue_empty(&hdev->cmd_q))
 			tasklet_schedule(&hdev->cmd_task);