commit | 399910534cca5f00d22438e80ecc7ccc7f4b8a14 | [log] [tgz] |
---|---|---|
author | Hartmut Knaack <knaack.h@gmx.de> | Fri Aug 28 23:59:58 2015 +0200 |
committer | Jonathan Cameron <jic23@kernel.org> | Sun Oct 11 15:45:17 2015 +0100 |
tree | e673942ffffdb8d8bf137b301855a6d7c3114840 | |
parent | acf2f67d055c656938a3980a0745ed62fb7985c9 [diff] |
iio:dac:m62332: use dynamic scale Some regulators can supply multiple voltages. To take changing voltages into account, the scale needs to be calculated on every read access. Signed-off-by: Hartmut Knaack <knaack.h@gmx.de> Signed-off-by: Jonathan Cameron <jic23@kernel.org>