iio:pressure:bmp280: cleanup
The calculations for temperature and pressure compensation were already slightly
optimized in comparison to the datasheet. So, it makes sense to optimize even a
bit more, making proper use of C operators:
- variable t in bmp280_compensate_temp() can be eliminated by directly
returning the result of the relevant equation.
- make use of the += operator and eliminate an unnecessary parenthesis level in
bmp280_compensate_press().
When the initialization of the ctrl_meas register fails, the error message will
now mention the right register name.
During probe, i2c_set_clientdata() is called, although it is not necessary. Drop
it.
Signed-off-by: Hartmut Knaack <knaack.h@gmx.de>
Reviewed-by: Vlad Dogaru <vlad.dogaru@intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
1 file changed