rx51_battery: Fix reporting temperature

This patch fixing units (1/10 °C) in which is temperature reported.

Signed-off-by: Pali Rohár <pali.rohar@gmail.com>
Signed-off-by: Anton Vorontsov <anton@enomsg.org>
diff --git a/drivers/power/rx51_battery.c b/drivers/power/rx51_battery.c
index f9dc9ff..1a1dcb8 100644
--- a/drivers/power/rx51_battery.c
+++ b/drivers/power/rx51_battery.c
@@ -119,7 +119,7 @@
 
 	/* First check for temperature in first direct table */
 	if (raw < ARRAY_SIZE(rx51_temp_table1))
-		return rx51_temp_table1[raw] * 100;
+		return rx51_temp_table1[raw] * 10;
 
 	/* Binary search RAW value in second inverse table */
 	while (max - min > 1) {
@@ -132,7 +132,7 @@
 			break;
 	}
 
-	return (rx51_temp_table2_first - min) * 100;
+	return (rx51_temp_table2_first - min) * 10;
 }
 
 /*