hpsa: generalize external arrays
External array LUNs must use target and lun numbers assigned by the
external array. So the driver must treat these differently from
local LUNs when assigning lun/target.
LUN's 'model' field has been used to detect Lun types that need
special treatment, but the desire is to eliminate the need to reference
specific array models, and support any external array.
Pass-through RAID (PTRAID) luns are not luns of the local controller,
so they are not reported in LUN count of command 'ID controller'.
However, they ARE reported in "Report logical Luns" command.
Local luns are listed first, then PTRAID LUNs.
The number of luns from "Report LUNs" in excess of those reported by
'ID controller' are therefore the PTRAID LUNS.
We can now remove function is_ext_target, and the 'white list'
array of supported model names.
Reviewed-by: Scott Teel <scott.teel@pmcs.com>
Reviewed-by: Justin Lindley <justin.lindley@pmcs.com>
Reviewed-by: Kevin Barnett <kevin.barnett@pmcs.com>
Signed-off-by: Don Brace <don.brace@pmcs.com>
Reviewed-by: Matthew R. Ochs <mrochs@linux.vnet.ibm.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
diff --git a/drivers/scsi/hpsa.c b/drivers/scsi/hpsa.c
index 0af4c67..1a67d63 100644
--- a/drivers/scsi/hpsa.c
+++ b/drivers/scsi/hpsa.c
@@ -275,7 +275,6 @@
static void hpsa_command_resubmit_worker(struct work_struct *work);
static u32 lockup_detected(struct ctlr_info *h);
static int detect_controller_lockup(struct ctlr_info *h);
-static int is_ext_target(struct ctlr_info *h, struct hpsa_scsi_dev_t *device);
static inline struct ctlr_info *sdev_to_hba(struct scsi_device *sdev)
{
@@ -776,7 +775,7 @@
hdev->bus, hdev->target, hdev->lun,
scsi_device_type(hdev->devtype));
- if (is_ext_target(h, hdev) ||
+ if (hdev->external ||
hdev->devtype == TYPE_RAID ||
is_logical_device(hdev)) {
output_len += snprintf(path[i] + output_len,
@@ -3034,6 +3033,35 @@
return rc;
}
+static int hpsa_bmic_id_controller(struct ctlr_info *h,
+ struct bmic_identify_controller *buf, size_t bufsize)
+{
+ int rc = IO_OK;
+ struct CommandList *c;
+ struct ErrorInfo *ei;
+
+ c = cmd_alloc(h);
+
+ rc = fill_cmd(c, BMIC_IDENTIFY_CONTROLLER, h, buf, bufsize,
+ 0, RAID_CTLR_LUNID, TYPE_CMD);
+ if (rc)
+ goto out;
+
+ rc = hpsa_scsi_do_simple_cmd_with_retry(h, c,
+ PCI_DMA_FROMDEVICE, NO_TIMEOUT);
+ if (rc)
+ goto out;
+ ei = c->err_info;
+ if (ei->CommandStatus != 0 && ei->CommandStatus != CMD_DATA_UNDERRUN) {
+ hpsa_scsi_interpret_error(h, c);
+ rc = -1;
+ }
+out:
+ cmd_free(h, c);
+ return rc;
+}
+
+
static int hpsa_bmic_id_physical_device(struct ctlr_info *h,
unsigned char scsi3addr[], u16 bmic_device_index,
struct bmic_identify_physical_device *buf, size_t bufsize)
@@ -3510,27 +3538,6 @@
}
}
-static unsigned char *ext_target_model[] = {
- "MSA2012",
- "MSA2024",
- "MSA2312",
- "MSA2324",
- "P2000 G3 SAS",
- "MSA 2040 SAS",
- NULL,
-};
-
-static int is_ext_target(struct ctlr_info *h, struct hpsa_scsi_dev_t *device)
-{
- int i;
-
- for (i = 0; ext_target_model[i]; i++)
- if (strncmp(device->model, ext_target_model[i],
- strlen(ext_target_model[i])) == 0)
- return 1;
- return 0;
-}
-
/*
* Helper function to assign bus, target, lun mapping of devices.
* Logical drive target and lun are assigned at this time, but
@@ -3554,7 +3561,7 @@
return;
}
/* It's a logical device */
- if (is_ext_target(h, device)) {
+ if (device->external) {
hpsa_set_bus_target_lun(device,
HPSA_EXTERNAL_RAID_VOLUME_BUS, (lunid >> 16) & 0x3fff,
lunid & 0x00ff);
@@ -3588,7 +3595,7 @@
if (!is_logical_dev_addr_mode(lunaddrbytes))
return 0; /* It's the logical targets that may lack lun 0. */
- if (!is_ext_target(h, tmpdevice))
+ if (!tmpdevice->external)
return 0; /* Only external target devices have this problem. */
if (tmpdevice->lun == 0) /* if lun is 0, then we have a lun 0. */
@@ -3647,6 +3654,27 @@
return 0;
}
+static int figure_external_status(struct ctlr_info *h, int raid_ctlr_position,
+ int i, int nphysicals, int nlocal_logicals)
+{
+ /* In report logicals, local logicals are listed first,
+ * then any externals.
+ */
+ int logicals_start = nphysicals + (raid_ctlr_position == 0);
+
+ if (i == raid_ctlr_position)
+ return 0;
+
+ if (i < logicals_start)
+ return 0;
+
+ /* i is in logicals range, but still within local logicals */
+ if ((i - nphysicals - (raid_ctlr_position == 0)) < nlocal_logicals)
+ return 0;
+
+ return 1; /* it's an external lun */
+}
+
/*
* Do CISS_REPORT_PHYS and CISS_REPORT_LOG. Data is returned in physdev,
* logdev. The number of luns in physdev and logdev are returned in
@@ -3770,6 +3798,32 @@
sizeof(this_device->bay));
}
+/* get number of local logical disks. */
+static int hpsa_set_local_logical_count(struct ctlr_info *h,
+ struct bmic_identify_controller *id_ctlr,
+ u32 *nlocals)
+{
+ int rc;
+
+ if (!id_ctlr) {
+ dev_warn(&h->pdev->dev, "%s: id_ctlr buffer is NULL.\n",
+ __func__);
+ return -ENOMEM;
+ }
+ memset(id_ctlr, 0, sizeof(*id_ctlr));
+ rc = hpsa_bmic_id_controller(h, id_ctlr, sizeof(*id_ctlr));
+ if (!rc)
+ if (id_ctlr->configured_logical_drive_count < 256)
+ *nlocals = id_ctlr->configured_logical_drive_count;
+ else
+ *nlocals = le16_to_cpu(
+ id_ctlr->extended_logical_unit_count);
+ else
+ *nlocals = -1;
+ return rc;
+}
+
+
static void hpsa_update_scsi_devices(struct ctlr_info *h)
{
/* the idea here is we could get notified
@@ -3785,8 +3839,10 @@
struct ReportExtendedLUNdata *physdev_list = NULL;
struct ReportLUNdata *logdev_list = NULL;
struct bmic_identify_physical_device *id_phys = NULL;
+ struct bmic_identify_controller *id_ctlr = NULL;
u32 nphysicals = 0;
u32 nlogicals = 0;
+ u32 nlocal_logicals = 0;
u32 ndev_allocated = 0;
struct hpsa_scsi_dev_t **currentsd, *this_device, *tmpdevice;
int ncurrent = 0;
@@ -3800,9 +3856,10 @@
logdev_list = kzalloc(sizeof(*logdev_list), GFP_KERNEL);
tmpdevice = kzalloc(sizeof(*tmpdevice), GFP_KERNEL);
id_phys = kzalloc(sizeof(*id_phys), GFP_KERNEL);
+ id_ctlr = kzalloc(sizeof(*id_ctlr), GFP_KERNEL);
if (!currentsd || !physdev_list || !logdev_list ||
- !tmpdevice || !id_phys) {
+ !tmpdevice || !id_phys || !id_ctlr) {
dev_err(&h->pdev->dev, "out of memory\n");
goto out;
}
@@ -3816,6 +3873,13 @@
goto out;
}
+ /* Set number of local logicals (non PTRAID) */
+ if (hpsa_set_local_logical_count(h, id_ctlr, &nlocal_logicals)) {
+ dev_warn(&h->pdev->dev,
+ "%s: Can't determine number of local logical devices.\n",
+ __func__);
+ }
+
/* We might see up to the maximum number of logical and physical disks
* plus external target devices, and a device for the local RAID
* controller.
@@ -3879,6 +3943,11 @@
continue;
}
+ /* Determine if this is a lun from an external target array */
+ tmpdevice->external =
+ figure_external_status(h, raid_ctlr_position, i,
+ nphysicals, nlocal_logicals);
+
figure_bus_target_lun(h, lunaddrbytes, tmpdevice);
hpsa_update_device_supports_aborts(h, tmpdevice, lunaddrbytes);
this_device = currentsd[ncurrent];
@@ -3962,6 +4031,7 @@
kfree(currentsd);
kfree(physdev_list);
kfree(logdev_list);
+ kfree(id_ctlr);
kfree(id_phys);
}
@@ -6414,6 +6484,23 @@
c->Request.CDB[7] = (size >> 16) & 0xFF;
c->Request.CDB[8] = (size >> 8) & 0XFF;
break;
+ case BMIC_IDENTIFY_CONTROLLER:
+ c->Request.CDBLen = 10;
+ c->Request.type_attr_dir =
+ TYPE_ATTR_DIR(cmd_type, ATTR_SIMPLE, XFER_READ);
+ c->Request.Timeout = 0;
+ c->Request.CDB[0] = BMIC_READ;
+ c->Request.CDB[1] = 0;
+ c->Request.CDB[2] = 0;
+ c->Request.CDB[3] = 0;
+ c->Request.CDB[4] = 0;
+ c->Request.CDB[5] = 0;
+ c->Request.CDB[6] = BMIC_IDENTIFY_CONTROLLER;
+ c->Request.CDB[7] = (size >> 16) & 0xFF;
+ c->Request.CDB[8] = (size >> 8) & 0XFF;
+ c->Request.CDB[9] = 0;
+ break;
+
default:
dev_warn(&h->pdev->dev, "unknown command 0x%c\n", cmd);
BUG();
diff --git a/drivers/scsi/hpsa.h b/drivers/scsi/hpsa.h
index a4cab12..ffcd4cb 100644
--- a/drivers/scsi/hpsa.h
+++ b/drivers/scsi/hpsa.h
@@ -77,6 +77,7 @@
struct hpsa_scsi_dev_t *phys_disk[RAID_MAP_MAX_ENTRIES];
int nphysical_disks;
int supports_aborts;
+ int external; /* 1-from external array 0-not <0-unknown */
};
struct reply_queue_buffer {
diff --git a/drivers/scsi/hpsa_cmd.h b/drivers/scsi/hpsa_cmd.h
index c2c0737..c83eaf1 100644
--- a/drivers/scsi/hpsa_cmd.h
+++ b/drivers/scsi/hpsa_cmd.h
@@ -286,6 +286,7 @@
#define BMIC_FLASH_FIRMWARE 0xF7
#define BMIC_SENSE_CONTROLLER_PARAMETERS 0x64
#define BMIC_IDENTIFY_PHYSICAL_DEVICE 0x15
+#define BMIC_IDENTIFY_CONTROLLER 0x11
/* Command List Structure */
union SCSI3Addr {
@@ -682,6 +683,16 @@
u32 board_id;
};
+struct bmic_identify_controller {
+ u8 configured_logical_drive_count; /* offset 0 */
+ u8 pad1[153];
+ __le16 extended_logical_unit_count; /* offset 154 */
+ u8 pad2[136];
+ u8 controller_mode; /* offset 292 */
+ u8 pad3[32];
+};
+
+
struct bmic_identify_physical_device {
u8 scsi_bus; /* SCSI Bus number on controller */
u8 scsi_id; /* SCSI ID on this bus */