clk: sunxi: Support factor clocks with N factor starting not from 0
The PLLs on newer Allwinner SoC's, such as the A31 and A23, have a
N multiplier factor that starts from 1, not 0.
This patch adds an option to the factor clk driver's config data
structures to specify the base value of N.
Signed-off-by: Chen-Yu Tsai <wens@csie.org>
Acked-by: Maxime Ripard <maxime.ripard@free-electrons.com>
Signed-off-by: Maxime Ripard <maxime.ripard@free-electrons.com>
diff --git a/drivers/clk/sunxi/clk-factors.c b/drivers/clk/sunxi/clk-factors.c
index 3806d97..2057c8a 100644
--- a/drivers/clk/sunxi/clk-factors.c
+++ b/drivers/clk/sunxi/clk-factors.c
@@ -62,7 +62,7 @@
p = FACTOR_GET(config->pshift, config->pwidth, reg);
/* Calculate the rate */
- rate = (parent_rate * n * (k + 1) >> p) / (m + 1);
+ rate = (parent_rate * (n + config->n_start) * (k + 1) >> p) / (m + 1);
return rate;
}