USB: ohci: fix 2 timers to fire at jiffies + 1s
Code inspection discovered in 2 places timers were being incorrectly setup
using round_jiffies_relative(HZ). The timer would then fire at time (0 <= T <
HZ).
Fix them to use round_jiffies(jiffies + HZ);
Signed-off-by: Richard Kennedy <richard@rsk.demon.co.uk>
Cc: Alan Stern <stern@rowland.harvard.edu>
Cc: David Brownell <david-b@pacbell.net>
Cc: Arjan van de Ven <arjan@infradead.org>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>
2 files changed