clk: qcom: Properly change rates for ahbix clock

The ahbix clock can never be turned off in practice. To change the
rates we need to switch the mux off the M/N counter to an always on
source (XO), reprogram the M/N counter to get the rate we want and
finally switch back to the M/N counter. Add a new ops structure
for this type of clock so that we can set the rate properly.

Fixes: c99e515a92e9 "clk: qcom: Add IPQ806X LPASS clock controller (LCC) driver"
Tested-by: Kenneth Westfield <kwestfie@codeaurora.org>
Signed-off-by: Stephen Boyd <sboyd@codeaurora.org>
diff --git a/drivers/clk/qcom/clk-rcg.h b/drivers/clk/qcom/clk-rcg.h
index 687e41f..d09d06b 100644
--- a/drivers/clk/qcom/clk-rcg.h
+++ b/drivers/clk/qcom/clk-rcg.h
@@ -96,6 +96,7 @@
 
 extern const struct clk_ops clk_rcg_ops;
 extern const struct clk_ops clk_rcg_bypass_ops;
+extern const struct clk_ops clk_rcg_lcc_ops;
 
 #define to_clk_rcg(_hw) container_of(to_clk_regmap(_hw), struct clk_rcg, clkr)