clk: qcom: Properly change rates for ahbix clock

The ahbix clock can never be turned off in practice. To change the
rates we need to switch the mux off the M/N counter to an always on
source (XO), reprogram the M/N counter to get the rate we want and
finally switch back to the M/N counter. Add a new ops structure
for this type of clock so that we can set the rate properly.

Fixes: c99e515a92e9 "clk: qcom: Add IPQ806X LPASS clock controller (LCC) driver"
Tested-by: Kenneth Westfield <kwestfie@codeaurora.org>
Signed-off-by: Stephen Boyd <sboyd@codeaurora.org>
diff --git a/drivers/clk/qcom/lcc-ipq806x.c b/drivers/clk/qcom/lcc-ipq806x.c
index 121ffde..5e4a3da 100644
--- a/drivers/clk/qcom/lcc-ipq806x.c
+++ b/drivers/clk/qcom/lcc-ipq806x.c
@@ -386,13 +386,12 @@
 	.freq_tbl = clk_tbl_ahbix,
 	.clkr = {
 		.enable_reg = 0x38,
-		.enable_mask = BIT(10), /* toggle the gfmux to select mn/pxo */
+		.enable_mask = BIT(11),
 		.hw.init = &(struct clk_init_data){
 			.name = "ahbix",
 			.parent_names = lcc_pxo_pll4,
 			.num_parents = 2,
-			.ops = &clk_rcg_ops,
-			.flags = CLK_SET_RATE_GATE,
+			.ops = &clk_rcg_lcc_ops,
 		},
 	},
 };