Input: ad714x - read the interrupt status registers in a row

The interrupt status registers should be read in row to avoid invalid data.

Alter "read" method for both bus options to allow reading several registers
in a row and make sure we read interrupt status registers properly.

Read sequence saves 50% of bus transactions compared to single register
reads. So use it also for the result registers, which are also located
in a row.

Also update copyright notice.

Signed-off-by: Michael Hennerich <michael.hennerich@analog.com>
Signed-off-by: Dmitry Torokhov <dtor@mail.ru>
diff --git a/drivers/input/misc/ad714x.h b/drivers/input/misc/ad714x.h
index d12d149..3c85455 100644
--- a/drivers/input/misc/ad714x.h
+++ b/drivers/input/misc/ad714x.h
@@ -1,7 +1,7 @@
 /*
  * AD714X CapTouch Programmable Controller driver (bus interfaces)
  *
- * Copyright 2009 Analog Devices Inc.
+ * Copyright 2009-2011 Analog Devices Inc.
  *
  * Licensed under the GPL-2 or later.
  */
@@ -18,12 +18,12 @@
 struct ad714x_driver_data;
 struct ad714x_chip;
 
-typedef int (*ad714x_read_t)(struct ad714x_chip *, unsigned short, unsigned short *);
+typedef int (*ad714x_read_t)(struct ad714x_chip *, unsigned short, unsigned short *, size_t);
 typedef int (*ad714x_write_t)(struct ad714x_chip *, unsigned short, unsigned short);
 
 struct ad714x_chip {
-	unsigned short h_state;
 	unsigned short l_state;
+	unsigned short h_state;
 	unsigned short c_state;
 	unsigned short adc_reg[STAGE_NUM];
 	unsigned short amb_reg[STAGE_NUM];