thermal: fix cpu_cooling max_level behavior
As per Documentation/thermal/sysfs-api.txt, max_level
is an index, not a counter. Thus, in case a CPU has
3 valid frequencies, max_level is expected to be 2, for instance.
The current code makes max_level == number of valid frequencies,
which is bogus. This patch fix the cpu_cooling device by
ranging max_level properly.
Reported-by: Carlos Hernandez <ceh@ti.com>
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
1 file changed