ima: switch to new template management mechanism
This patch performs the switch to the new template mechanism by modifying
the functions ima_alloc_init_template(), ima_measurements_show() and
ima_ascii_measurements_show(). The old function ima_template_show() was
removed as it is no longer needed. Also, if the template descriptor used
to generate a measurement entry is not 'ima', the whole length of field
data stored for an entry is provided before the data itself through the
binary_runtime_measurement interface.
Changelog:
- unnecessary to use strncmp() (Mimi Zohar)
- create new variable 'field' in ima_alloc_init_template() (Roberto Sassu)
- use GFP_NOFS flag in ima_alloc_init_template() (Roberto Sassu)
- new variable 'num_fields' in ima_store_template() (Roberto Sassu,
proposed by Mimi Zohar)
- rename ima_calc_buffer_hash/template_hash() to ima_calc_field_array_hash(),
something more generic (Mimi, requested by Dmitry)
- sparse error fix - Fengguang Wu
- fix lindent warnings
- always include the field length in the template data length
- include the template field length variable size in the template data length
- include both the template field data and field length in the template digest
calculation. Simplifies verifying the template digest. (Mimi)
Signed-off-by: Roberto Sassu <roberto.sassu@polito.it>
Signed-off-by: Mimi Zohar <zohar@linux.vnet.ibm.com>
5 files changed