bonding: prevent sysfs from allowing arp monitoring with alb/tlb
When using module options arp monitoring and balance-alb/balance-tlb
are mutually exclusive options. Anytime balance-alb/balance-tlb are
enabled mii monitoring is forced to 100ms if not set. When configuring
via sysfs no checking is currently done.
Handling these cases with sysfs has to be done a bit differently because
we do not have all configuration information available at once. This
patch will not allow a mode change to balance-alb/balance-tlb if
arp_interval is already non-zero. It will also not allow the user to
set a non-zero arp_interval value if the mode is already set to
balance-alb/balance-tlb. They are still mutually exclusive on a
first-come, first serve basis.
Tested with initscripts on Fedora and manual setting via sysfs.
Signed-off-by: Andy Gospodarek <gospo@redhat.com>
Signed-off-by: Jay Vosburgh <fubar@us.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
diff --git a/drivers/net/bonding/bond_sysfs.c b/drivers/net/bonding/bond_sysfs.c
index 1a99764..c311aed 100644
--- a/drivers/net/bonding/bond_sysfs.c
+++ b/drivers/net/bonding/bond_sysfs.c
@@ -313,19 +313,26 @@
bond->dev->name, (int)strlen(buf) - 1, buf);
ret = -EINVAL;
goto out;
- } else {
- if (bond->params.mode == BOND_MODE_8023AD)
- bond_unset_master_3ad_flags(bond);
-
- if (bond->params.mode == BOND_MODE_ALB)
- bond_unset_master_alb_flags(bond);
-
- bond->params.mode = new_value;
- bond_set_mode_ops(bond, bond->params.mode);
- pr_info("%s: setting mode to %s (%d).\n",
- bond->dev->name, bond_mode_tbl[new_value].modename,
- new_value);
}
+ if ((new_value == BOND_MODE_ALB ||
+ new_value == BOND_MODE_TLB) &&
+ bond->params.arp_interval) {
+ pr_err("%s: %s mode is incompatible with arp monitoring.\n",
+ bond->dev->name, bond_mode_tbl[new_value].modename);
+ ret = -EINVAL;
+ goto out;
+ }
+ if (bond->params.mode == BOND_MODE_8023AD)
+ bond_unset_master_3ad_flags(bond);
+
+ if (bond->params.mode == BOND_MODE_ALB)
+ bond_unset_master_alb_flags(bond);
+
+ bond->params.mode = new_value;
+ bond_set_mode_ops(bond, bond->params.mode);
+ pr_info("%s: setting mode to %s (%d).\n",
+ bond->dev->name, bond_mode_tbl[new_value].modename,
+ new_value);
out:
return ret;
}
@@ -510,7 +517,13 @@
ret = -EINVAL;
goto out;
}
-
+ if (bond->params.mode == BOND_MODE_ALB ||
+ bond->params.mode == BOND_MODE_TLB) {
+ pr_info("%s: ARP monitoring cannot be used with ALB/TLB. Only MII monitoring is supported on %s.\n",
+ bond->dev->name, bond->dev->name);
+ ret = -EINVAL;
+ goto out;
+ }
pr_info("%s: Setting ARP monitoring interval to %d.\n",
bond->dev->name, new_value);
bond->params.arp_interval = new_value;