omap-i2c: fix incorrect log message when using a device tree
When booting using a device tree, the adapter number is dynamically
assigned after the log message is sent.
This patch modifies the log message to get a correct adapter id.
Signed-off-by: Florian Vaussard <florian.vaussard@epfl.ch>
Tested-by: Benoit Cousson <b-cousson@ti.com>
Acked-by: Shubhrajyoti D <shubhrajyoti@ti.com>
Signed-off-by: Wolfram Sang <w.sang@pengutronix.de>
diff --git a/drivers/i2c/busses/i2c-omap.c b/drivers/i2c/busses/i2c-omap.c
index b149e32..c78431a 100644
--- a/drivers/i2c/busses/i2c-omap.c
+++ b/drivers/i2c/busses/i2c-omap.c
@@ -1175,9 +1175,6 @@
goto err_unuse_clocks;
}
- dev_info(dev->dev, "bus %d rev%d.%d.%d at %d kHz\n", pdev->id,
- dev->dtrev, dev->rev >> 4, dev->rev & 0xf, dev->speed);
-
adap = &dev->adapter;
i2c_set_adapdata(adap, dev);
adap->owner = THIS_MODULE;
@@ -1195,6 +1192,9 @@
goto err_unuse_clocks;
}
+ dev_info(dev->dev, "bus %d rev%d.%d.%d at %d kHz\n", adap->nr,
+ dev->dtrev, dev->rev >> 4, dev->rev & 0xf, dev->speed);
+
of_i2c_register_devices(adap);
pm_runtime_mark_last_busy(dev->dev);