hwmon: (pmbus/lm25066) Add support for LM25063

Signed-off-by: Guenter Roeck <linux@roeck-us.net>
diff --git a/Documentation/hwmon/lm25066 b/Documentation/hwmon/lm25066
index c1b57d7..b34c3de 100644
--- a/Documentation/hwmon/lm25066
+++ b/Documentation/hwmon/lm25066
@@ -8,6 +8,11 @@
     Datasheets:
 	http://www.ti.com/lit/gpn/lm25056
 	http://www.ti.com/lit/gpn/lm25056a
+  * TI LM25063
+    Prefix: 'lm25063'
+    Addresses scanned: -
+    Datasheet:
+	To be announced
   * National Semiconductor LM25066
     Prefix: 'lm25066'
     Addresses scanned: -
@@ -32,7 +37,7 @@
 -----------
 
 This driver supports hardware montoring for National Semiconductor / TI LM25056,
-LM25066, LM5064, and LM5064 Power Management, Monitoring, Control, and
+LM25063, LM25066, LM5064, and LM5066 Power Management, Monitoring, Control, and
 Protection ICs.
 
 The driver is a client driver to the core PMBus driver. Please see
@@ -64,8 +69,12 @@
 in1_average		Average measured input voltage.
 in1_min			Minimum input voltage.
 in1_max			Maximum input voltage.
+in1_crit		Critical high input voltage (LM25063 only).
+in1_lcrit		Critical low input voltage (LM25063 only).
 in1_min_alarm		Input voltage low alarm.
 in1_max_alarm		Input voltage high alarm.
+in1_lcrit_alarm		Input voltage critical low alarm (LM25063 only).
+in1_crit_alarm		Input voltage critical high alarm. (LM25063 only).
 
 in2_label		"vmon"
 in2_input		Measured voltage on VAUX pin
@@ -80,12 +89,16 @@
 in3_average		Average measured output voltage.
 in3_min			Minimum output voltage.
 in3_min_alarm		Output voltage low alarm.
+in3_highest		Historical minimum output voltage (LM25063 only).
+in3_lowest		Historical maximum output voltage (LM25063 only).
 
 curr1_label		"iin"
 curr1_input		Measured input current.
 curr1_average		Average measured input current.
 curr1_max		Maximum input current.
+curr1_crit		Critical input current (LM25063 only).
 curr1_max_alarm		Input current high alarm.
+curr1_crit_alarm	Input current critical high alarm (LM25063 only).
 
 power1_label		"pin"
 power1_input		Measured input power.
@@ -95,6 +108,11 @@
 power1_input_highest	Historical maximum power.
 power1_reset_history	Write any value to reset maximum power history.
 
+power2_label		"pout". LM25063 only.
+power2_input		Measured output power.
+power2_max		Maximum output power limit.
+power2_crit		Critical output power limit.
+
 temp1_input		Measured temperature.
 temp1_max		Maximum temperature.
 temp1_crit		Critical high temperature.