clocksource/drivers/prima2: Prevent ftrace recursion
Currently prima2 timer can be used as a scheduler clock. We properly
marked sirfsoc_read_sched_clock() as notrace but we then call another
function sirfsoc_timer_read() that _wasn't_ notrace.
Having a traceable function in the sched_clock() path leads to a recursion
within ftrace and a kernel crash.
Fix this by adding notrace attribute to the sirfsoc_timer_read() function.
Signed-off-by: Jisheng Zhang <jszhang@marvell.com>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
diff --git a/drivers/clocksource/timer-prima2.c b/drivers/clocksource/timer-prima2.c
index 78de982..2854c66 100644
--- a/drivers/clocksource/timer-prima2.c
+++ b/drivers/clocksource/timer-prima2.c
@@ -73,7 +73,7 @@
}
/* read 64-bit timer counter */
-static cycle_t sirfsoc_timer_read(struct clocksource *cs)
+static cycle_t notrace sirfsoc_timer_read(struct clocksource *cs)
{
u64 cycles;