megaraid_sas : N-drive primary raid level 1 load balancing
Resending the patch. Addressed the review comments from Tomas Henzl.
Current driver does fast path read load balancing between arm and mirror disk
for two Drive Raid-1 configuration only.
Now, Driver support fast path read load balancing for all (any number of disk) Raid-1 configuration.
Signed-off-by: Sumit Saxena <sumit.saxena@avagotech.com>
Signed-off-by: Kashyap Desai <kashyap.desai@avagotech.com>
Reviewed-by: Tomas Henzl <thenzl@redhat.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
diff --git a/drivers/scsi/megaraid/megaraid_sas_fusion.h b/drivers/scsi/megaraid/megaraid_sas_fusion.h
index 065c270..7584426 100644
--- a/drivers/scsi/megaraid/megaraid_sas_fusion.h
+++ b/drivers/scsi/megaraid/megaraid_sas_fusion.h
@@ -630,6 +630,8 @@
u8 start_span;
u8 reserved;
u64 start_row;
+ u8 span_arm; /* span[7:5], arm[4:0] */
+ u8 pd_after_lb;
};
struct MR_LD_TARGET_SYNC {
@@ -681,14 +683,14 @@
u32 sync_cmd_idx;
u32 index;
u8 flags;
+ u8 pd_r1_lb;
};
struct LD_LOAD_BALANCE_INFO {
u8 loadBalanceFlag;
u8 reserved1;
- u16 raid1DevHandle[2];
- atomic_t scsi_pending_cmds[2];
- u64 last_accessed_block[2];
+ atomic_t scsi_pending_cmds[MAX_PHYSICAL_DEVICES];
+ u64 last_accessed_block[MAX_PHYSICAL_DEVICES];
};
/* SPAN_SET is info caclulated from span info from Raid map per LD */