mmc: mmc: Relax checking for switch errors after HS200 switch

The JEDEC specification indicates CMD13 can be used after a HS200 switch
to check for errors. However in practice some boards experience CRC errors
in the CMD13 response. Consequently, for HS200, CRC errors are not a
reliable way to know the switch failed. If there really is a problem, we
would expect tuning will fail and the result ends up the same. So change
the error condition to ignore CRC errors in that case.

Signed-off-by: Adrian Hunter <adrian.hunter@intel.com>
Acked-by: Jaehoon Chung <jh80.chung@samsung.com>
Reviewed-by: Shawn Lin <shawn.lin@rock-chips.com>
Signed-off-by: Ulf Hansson <ulf.hansson@linaro.org>
3 files changed