commit | ef6fcea37f014ec54a0a9f7eaecc78cdb6ffc71e | [log] [tgz] |
---|---|---|
author | Vivien Didelot <vivien.didelot@savoirfairelinux.com> | Mon May 01 14:05:20 2017 -0400 |
committer | David S. Miller <davem@davemloft.net> | Mon May 01 15:03:11 2017 -0400 |
tree | b87e509a726da487ecd82c856ee4071a3bc7a8b6 | |
parent | 66a8e1f93319b8e3f5b6e81c06a2534c1491157c [diff] |
net: dsa: mv88e6xxx: get STU entry on VTU GetNext Now that the code reads both VTU and STU data on VTU GetNext operation, fetch the STU entry data of a VTU entry at the same time. The STU data bits are masked with the VTU data bits and they are now all read at the same time a VTU GetNext operation is issued. Signed-off-by: Vivien Didelot <vivien.didelot@savoirfairelinux.com> Reviewed-by: Andrew Lunn <andrew@lunn.ch> Signed-off-by: David S. Miller <davem@davemloft.net>