Zhang Rui203d3d42008-01-17 15:51:08 +08001#
2# Generic thermal sysfs drivers configuration
3#
4
5menuconfig THERMAL
Zhang Rui63c4ec92008-04-21 16:07:13 +08006 tristate "Generic Thermal sysfs driver"
Zhang Rui203d3d42008-01-17 15:51:08 +08007 help
8 Generic Thermal Sysfs driver offers a generic mechanism for
9 thermal management. Usually it's made up of one or more thermal
10 zone and cooling device.
Len Brown543a9562008-02-07 16:55:08 -050011 Each thermal zone contains its own temperature, trip points,
Zhang Rui203d3d42008-01-17 15:51:08 +080012 cooling devices.
13 All platforms with ACPI thermal support can use this driver.
Zhang Rui63c4ec92008-04-21 16:07:13 +080014 If you want this support, you should say Y or M here.
Rene Herman16d75232008-06-24 19:38:56 +020015
Zhang Rui72e19892012-11-15 09:16:20 +080016if THERMAL
17
Rene Herman16d75232008-06-24 19:38:56 +020018config THERMAL_HWMON
Jean Delvareab924022011-07-28 13:48:40 -070019 bool
Eduardo Valentin0dd88792013-07-03 15:14:28 -040020 prompt "Expose thermal sensors as hwmon device"
Rene Herman16d75232008-06-24 19:38:56 +020021 depends on HWMON=y || HWMON=THERMAL
Jean Delvareab924022011-07-28 13:48:40 -070022 default y
Eduardo Valentin0dd88792013-07-03 15:14:28 -040023 help
24 In case a sensor is registered with the thermal
25 framework, this option will also register it
26 as a hwmon. The sensor will then have the common
27 hwmon sysfs interface.
28
29 Say 'Y' here if you want all thermal sensors to
30 have hwmon sysfs interface too.
Vincenzo Frascino6a92c362012-03-21 12:55:03 -070031
Eduardo Valentin4e5e4702013-07-03 15:35:39 -040032config THERMAL_OF
33 bool
34 prompt "APIs to parse thermal data out of device tree"
35 depends on OF
36 default y
37 help
38 This options provides helpers to add the support to
39 read and parse thermal data definitions out of the
40 device tree blob.
41
42 Say 'Y' here if you need to build thermal infrastructure
43 based on device tree.
44
Punit Agrawal35e94642015-03-03 10:43:03 +000045config THERMAL_WRITABLE_TRIPS
46 bool "Enable writable trip points"
47 help
48 This option allows the system integrator to choose whether
49 trip temperatures can be changed from userspace. The
50 writable trips need to be specified when setting up the
51 thermal zone but the choice here takes precedence.
52
53 Say 'Y' here if you would like to allow userspace tools to
54 change trip temperatures.
55
Durgadoss Ra56757a2012-09-21 14:32:24 +053056choice
57 prompt "Default Thermal governor"
Durgadoss Ra56757a2012-09-21 14:32:24 +053058 default THERMAL_DEFAULT_GOV_STEP_WISE
59 help
60 This option sets which thermal governor shall be loaded at
61 startup. If in doubt, select 'step_wise'.
62
63config THERMAL_DEFAULT_GOV_STEP_WISE
64 bool "step_wise"
Zhang Rui9d185d02013-02-08 20:33:42 +080065 select THERMAL_GOV_STEP_WISE
Durgadoss Ra56757a2012-09-21 14:32:24 +053066 help
67 Use the step_wise governor as default. This throttles the
68 devices one step at a time.
69
70config THERMAL_DEFAULT_GOV_FAIR_SHARE
71 bool "fair_share"
Zhang Rui9d185d02013-02-08 20:33:42 +080072 select THERMAL_GOV_FAIR_SHARE
Durgadoss Ra56757a2012-09-21 14:32:24 +053073 help
74 Use the fair_share governor as default. This throttles the
75 devices based on their 'contribution' to a zone. The
76 contribution should be provided through platform data.
77
78config THERMAL_DEFAULT_GOV_USER_SPACE
79 bool "user_space"
Zhang Rui9d185d02013-02-08 20:33:42 +080080 select THERMAL_GOV_USER_SPACE
Durgadoss Ra56757a2012-09-21 14:32:24 +053081 help
82 Select this if you want to let the user space manage the
Regid Ichiraece238f2013-09-09 00:58:53 +030083 platform thermals.
Zhang Rui72e19892012-11-15 09:16:20 +080084
Javi Merino6b775e82015-03-02 17:17:19 +000085config THERMAL_DEFAULT_GOV_POWER_ALLOCATOR
86 bool "power_allocator"
87 select THERMAL_GOV_POWER_ALLOCATOR
88 help
89 Select this if you want to control temperature based on
90 system and device power allocation. This governor can only
91 operate on cooling devices that implement the power API.
92
Durgadoss Ra56757a2012-09-21 14:32:24 +053093endchoice
Zhang Rui72e19892012-11-15 09:16:20 +080094
Zhang Rui9d185d02013-02-08 20:33:42 +080095config THERMAL_GOV_FAIR_SHARE
Zhang Rui72e19892012-11-15 09:16:20 +080096 bool "Fair-share thermal governor"
97 help
98 Enable this to manage platform thermals using fair-share governor.
99
Zhang Rui9d185d02013-02-08 20:33:42 +0800100config THERMAL_GOV_STEP_WISE
Zhang Rui72e19892012-11-15 09:16:20 +0800101 bool "Step_wise thermal governor"
102 help
103 Enable this to manage platform thermals using a simple linear
Luka Perkova8227942013-09-27 20:20:33 +0200104 governor.
Zhang Rui72e19892012-11-15 09:16:20 +0800105
Peter Feuerere4dbf982014-07-22 17:37:13 +0200106config THERMAL_GOV_BANG_BANG
107 bool "Bang Bang thermal governor"
108 default n
109 help
110 Enable this to manage platform thermals using bang bang governor.
111
112 Say 'Y' here if you want to use two point temperature regulation
113 used for fans without throttling. Some fan drivers depend on this
114 governor to be enabled (e.g. acerhdf).
115
Zhang Rui9d185d02013-02-08 20:33:42 +0800116config THERMAL_GOV_USER_SPACE
Zhang Rui72e19892012-11-15 09:16:20 +0800117 bool "User_space thermal governor"
118 help
119 Enable this to let the user space manage the platform thermals.
120
Javi Merino6b775e82015-03-02 17:17:19 +0000121config THERMAL_GOV_POWER_ALLOCATOR
122 bool "Power allocator thermal governor"
Javi Merino6b775e82015-03-02 17:17:19 +0000123 help
124 Enable this to manage platform thermals by dynamically
125 allocating and limiting power to devices.
126
Zhang Rui72e19892012-11-15 09:16:20 +0800127config CPU_THERMAL
Zhang Ruibbf7fc82013-03-26 23:57:01 +0800128 bool "generic cpu cooling support"
Zhang Rui72e19892012-11-15 09:16:20 +0800129 depends on CPU_FREQ
Eduardo Valentin39d99cf2013-09-12 19:26:45 -0400130 depends on THERMAL_OF
Zhang Rui72e19892012-11-15 09:16:20 +0800131 help
132 This implements the generic cpu cooling mechanism through frequency
Eduardo Valentinf7188b32013-04-17 17:12:10 +0000133 reduction. An ACPI version of this already exists
134 (drivers/acpi/processor_thermal.c).
Zhang Rui72e19892012-11-15 09:16:20 +0800135 This will be useful for platforms using the generic thermal interface
136 and not the ACPI interface.
Eduardo Valentinf7188b32013-04-17 17:12:10 +0000137
Zhang Rui72e19892012-11-15 09:16:20 +0800138 If you want this support, you should say Y here.
139
Eduardo Valentinf9df89d2014-01-06 09:04:18 -0400140config CLOCK_THERMAL
141 bool "Generic clock cooling support"
142 depends on COMMON_CLK
143 depends on PM_OPP
144 help
145 This entry implements the generic clock cooling mechanism through
146 frequency clipping. Typically used to cool off co-processors. The
147 device that is configured to use this cooling mechanism will be
148 controlled to reduce clock frequency whenever temperature is high.
149
Ørjan Eidea76caf52015-09-10 18:09:30 +0100150config DEVFREQ_THERMAL
151 bool "Generic device cooling support"
152 depends on PM_DEVFREQ
153 depends on PM_OPP
154 help
155 This implements the generic devfreq cooling mechanism through
156 frequency reduction for devices using devfreq.
157
158 This will throttle the device by limiting the maximum allowed DVFS
159 frequency corresponding to the cooling level.
160
161 In order to use the power extensions of the cooling device,
162 devfreq should use the simple_ondemand governor.
163
Eduardo Valentinf9df89d2014-01-06 09:04:18 -0400164 If you want this support, you should say Y here.
165
Amit Daniel Kachhape6e238c2013-02-04 00:30:15 +0000166config THERMAL_EMULATION
167 bool "Thermal emulation mode support"
168 help
169 Enable this option to make a emul_temp sysfs node in thermal zone
170 directory to support temperature emulation. With emulation sysfs node,
171 user can manually input temperature and test the different trip
172 threshold behaviour for simulation purpose.
173
Eduardo Valentin88372952013-03-26 21:38:34 +0000174 WARNING: Be careful while enabling this option on production systems,
175 because userland can easily disable the thermal policy by simply
176 flooding this sysfs node with low temperature values.
177
kongxinwei9a5238a2015-05-20 19:16:37 +0800178config HISI_THERMAL
179 tristate "Hisilicon thermal driver"
Eduardo Valentinf9e2b052015-09-09 20:39:44 -0700180 depends on (ARCH_HISI && CPU_THERMAL && OF) || COMPILE_TEST
Krzysztof Kozlowskibf82c352016-03-04 10:03:59 +0900181 depends on HAS_IOMEM
kongxinwei9a5238a2015-05-20 19:16:37 +0800182 help
183 Enable this to plug hisilicon's thermal sensor driver into the Linux
184 thermal framework. cpufreq is used as the cooling device to throttle
185 CPUs when the passive trip is crossed.
186
Shawn Guoca3de462013-06-24 14:30:44 +0800187config IMX_THERMAL
188 tristate "Temperature sensor driver for Freescale i.MX SoCs"
189 depends on CPU_THERMAL
190 depends on MFD_SYSCON
191 depends on OF
192 help
193 Support for Temperature Monitor (TEMPMON) found on Freescale i.MX SoCs.
194 It supports one critical trip point and one passive trip point. The
195 cpufreq is used as the cooling device to throttle CPUs when the
196 passive trip is crossed.
197
Zhang Rui72e19892012-11-15 09:16:20 +0800198config SPEAR_THERMAL
Arnd Bergmann4d2f1792016-01-25 17:44:11 +0100199 tristate "SPEAr thermal sensor driver"
Eduardo Valentinaa2937b2015-09-09 20:42:01 -0700200 depends on PLAT_SPEAR || COMPILE_TEST
Krzysztof Kozlowskibf82c352016-03-04 10:03:59 +0900201 depends on HAS_IOMEM
Zhang Rui72e19892012-11-15 09:16:20 +0800202 depends on OF
203 help
204 Enable this to plug the SPEAr thermal sensor driver into the Linux
Luka Perkova8227942013-09-27 20:20:33 +0200205 thermal framework.
Zhang Rui72e19892012-11-15 09:16:20 +0800206
Caesar Wangcbac8f632014-11-24 12:58:59 +0800207config ROCKCHIP_THERMAL
208 tristate "Rockchip thermal driver"
Eduardo Valentin444f9b02015-09-09 20:43:57 -0700209 depends on ARCH_ROCKCHIP || COMPILE_TEST
Caesar Wangcbac8f632014-11-24 12:58:59 +0800210 depends on RESET_CONTROLLER
Krzysztof Kozlowskibf82c352016-03-04 10:03:59 +0900211 depends on HAS_IOMEM
Caesar Wangcbac8f632014-11-24 12:58:59 +0800212 help
213 Rockchip thermal driver provides support for Temperature sensor
214 ADC (TS-ADC) found on Rockchip SoCs. It supports one critical
215 trip point. Cpufreq is used as the cooling device and will throttle
216 CPUs when the Temperature crosses the passive trip point.
217
Zhang Rui72e19892012-11-15 09:16:20 +0800218config RCAR_THERMAL
219 tristate "Renesas R-Car thermal driver"
Simon Horman8255e4e2016-03-02 11:04:26 +0900220 depends on ARCH_RENESAS || COMPILE_TEST
Richard Weinbergerd1c8b042014-01-27 09:40:58 +0100221 depends on HAS_IOMEM
Zhang Rui72e19892012-11-15 09:16:20 +0800222 help
223 Enable this to plug the R-Car thermal sensor driver into the Linux
Luka Perkova8227942013-09-27 20:20:33 +0200224 thermal framework.
Zhang Rui72e19892012-11-15 09:16:20 +0800225
Nobuhiro Iwamatsu7060aa32013-02-06 06:35:24 +0000226config KIRKWOOD_THERMAL
227 tristate "Temperature sensor on Marvell Kirkwood SoCs"
Eduardo Valentin9c8aa952015-09-09 20:44:46 -0700228 depends on MACH_KIRKWOOD || COMPILE_TEST
Krzysztof Kozlowskibf82c352016-03-04 10:03:59 +0900229 depends on HAS_IOMEM
Nobuhiro Iwamatsu7060aa32013-02-06 06:35:24 +0000230 depends on OF
231 help
232 Support for the Kirkwood thermal sensor driver into the Linux thermal
233 framework. Only kirkwood 88F6282 and 88F6283 have this sensor.
234
Andrew Lunn74ffa642013-02-06 06:35:26 +0000235config DOVE_THERMAL
236 tristate "Temperature sensor on Marvell Dove SoCs"
Eduardo Valentin07fffd52015-09-09 20:45:25 -0700237 depends on ARCH_DOVE || MACH_DOVE || COMPILE_TEST
Krzysztof Kozlowskibf82c352016-03-04 10:03:59 +0900238 depends on HAS_IOMEM
Andrew Lunn74ffa642013-02-06 06:35:26 +0000239 depends on OF
240 help
241 Support for the Dove thermal sensor driver in the Linux thermal
242 framework.
243
hongbo.zhangaa1acb02012-11-15 18:56:42 +0800244config DB8500_THERMAL
Arnd Bergmann26716ce2016-01-25 17:44:12 +0100245 tristate "DB8500 thermal management"
246 depends on MFD_DB8500_PRCMU
hongbo.zhangaa1acb02012-11-15 18:56:42 +0800247 default y
248 help
249 Adds DB8500 thermal management implementation according to the thermal
250 management framework. A thermal zone with several trip points will be
251 created. Cooling devices can be bound to the trip points to cool this
252 thermal zone if trip points reached.
253
Ezequiel Garciafa0d6542013-04-02 01:37:41 +0000254config ARMADA_THERMAL
255 tristate "Armada 370/XP thermal management"
Eduardo Valentin1b158262015-09-09 20:48:00 -0700256 depends on ARCH_MVEBU || COMPILE_TEST
Krzysztof Kozlowskibf82c352016-03-04 10:03:59 +0900257 depends on HAS_IOMEM
Ezequiel Garciafa0d6542013-04-02 01:37:41 +0000258 depends on OF
259 help
260 Enable this option if you want to have support for thermal management
261 controller present in Armada 370 and Armada XP SoC.
262
Mikko Perttunen66fb8482014-09-29 17:17:31 +0300263config TEGRA_SOCTHERM
264 tristate "Tegra SOCTHERM thermal management"
265 depends on ARCH_TEGRA
266 help
267 Enable this option for integrated thermal management support on NVIDIA
268 Tegra124 systems-on-chip. The driver supports four thermal zones
269 (CPU, GPU, MEM, PLLX). Cooling devices can be bound to the thermal
270 zones to manage temperatures. This option is also required for the
271 emergency thermal reset (thermtrip) feature to function.
272
hongbo.zhangaa1acb02012-11-15 18:56:42 +0800273config DB8500_CPUFREQ_COOLING
274 tristate "DB8500 cpufreq cooling"
Luis de Bethencourt527860f2015-10-14 19:43:29 +0100275 depends on ARCH_U8500 || COMPILE_TEST
Krzysztof Kozlowskibf82c352016-03-04 10:03:59 +0900276 depends on HAS_IOMEM
hongbo.zhangaa1acb02012-11-15 18:56:42 +0800277 depends on CPU_THERMAL
278 default y
279 help
280 Adds DB8500 cpufreq cooling devices, and these cooling devices can be
281 bound to thermal zone trip points. When a trip point reached, the
282 bound cpufreq cooling device turns active to set CPU frequency low to
283 cool down the CPU.
Zhang Rui72e19892012-11-15 09:16:20 +0800284
Jacob Pand6d71ee2013-01-21 04:37:57 -0800285config INTEL_POWERCLAMP
286 tristate "Intel PowerClamp idle injection driver"
287 depends on THERMAL
288 depends on X86
289 depends on CPU_SUP_INTEL
290 help
291 Enable this to enable Intel PowerClamp idle injection driver. This
292 enforce idle time which results in more package C-state residency. The
293 user interface is exposed via generic thermal framework.
294
Srinivas Pandruvadaf1a18a12013-05-17 23:42:02 +0000295config X86_PKG_TEMP_THERMAL
296 tristate "X86 package temperature thermal driver"
Randy Dunlapb3ba0202013-06-17 12:27:17 -0700297 depends on X86_THERMAL_VECTOR
Srinivas Pandruvadaf1a18a12013-05-17 23:42:02 +0000298 select THERMAL_GOV_USER_SPACE
Srinivas Pandruvada98cadf22015-08-03 04:13:16 -0700299 select THERMAL_WRITABLE_TRIPS
Srinivas Pandruvadaf1a18a12013-05-17 23:42:02 +0000300 default m
301 help
302 Enable this to register CPU digital sensor for package temperature as
303 thermal zone. Each package will have its own thermal zone. There are
304 two trip points which can be set by user to get notifications via thermal
305 notification methods.
306
Srinivas Pandruvadaee073602015-03-02 13:12:58 -0800307config INTEL_SOC_DTS_IOSF_CORE
308 tristate
309 depends on X86
310 select IOSF_MBI
311 help
312 This is becoming a common feature for Intel SoCs to expose the additional
313 digital temperature sensors (DTSs) using side band interface (IOSF). This
314 implements the common set of helper functions to register, get temperature
315 and get/set thresholds on DTSs.
316
Srinivas Pandruvadabc40b5e2014-04-07 13:57:15 -0700317config INTEL_SOC_DTS_THERMAL
318 tristate "Intel SoCs DTS thermal driver"
Srinivas Pandruvada3a2419f2015-03-02 13:12:59 -0800319 depends on X86
320 select INTEL_SOC_DTS_IOSF_CORE
Srinivas Pandruvada98cadf22015-08-03 04:13:16 -0700321 select THERMAL_WRITABLE_TRIPS
Srinivas Pandruvadabc40b5e2014-04-07 13:57:15 -0700322 help
323 Enable this to register Intel SoCs (e.g. Bay Trail) platform digital
324 temperature sensor (DTS). These SoCs have two additional DTSs in
325 addition to DTSs on CPU cores. Each DTS will be registered as a
326 thermal zone. There are two trip points. One of the trip point can
327 be set by user mode programs to get notifications via Linux thermal
328 notification methods.The other trip is a critical trip point, which
329 was set by the driver based on the TJ MAX temperature.
330
Ong, Boon Leong8c187692015-04-15 10:08:15 +0800331config INTEL_QUARK_DTS_THERMAL
332 tristate "Intel Quark DTS thermal driver"
333 depends on X86_INTEL_QUARK
334 help
335 Enable this to register Intel Quark SoC (e.g. X1000) platform digital
336 temperature sensor (DTS). For X1000 SoC, it has one on-die DTS.
337 The DTS will be registered as a thermal zone. There are two trip points:
338 hot & critical. The critical trip point default value is set by
339 underlying BIOS/Firmware.
340
Zhang Rui3230bbf2014-03-14 00:34:05 +0800341config INT340X_THERMAL
Zhang Rui816cab92014-03-14 12:45:05 +0800342 tristate "ACPI INT340X thermal drivers"
Zhang Rui3230bbf2014-03-14 00:34:05 +0800343 depends on X86 && ACPI
Zhang Rui0ab15362014-03-23 23:37:32 +0800344 select THERMAL_GOV_USER_SPACE
Jacob Pan52b1c692014-09-03 15:14:23 +0800345 select ACPI_THERMAL_REL
Zhang Ruid8054742014-06-19 15:43:29 +0800346 select ACPI_FAN
Srinivas Pandruvada4d0dd6c2015-03-02 13:13:00 -0800347 select INTEL_SOC_DTS_IOSF_CORE
Srinivas Pandruvada98cadf22015-08-03 04:13:16 -0700348 select THERMAL_WRITABLE_TRIPS
Zhang Rui3230bbf2014-03-14 00:34:05 +0800349 help
350 Newer laptops and tablets that use ACPI may have thermal sensors and
351 other devices with thermal control capabilities outside the core
352 CPU/SOC, for thermal safety reasons.
353 They are exposed for the OS to use via the INT3400 ACPI device object
354 as the master, and INT3401~INT340B ACPI device objects as the slaves.
355 Enable this to expose the temperature information and cooling ability
356 from these objects to userspace via the normal thermal framework.
357 This means that a wide range of applications and GUI widgets can show
358 the information to the user or use this information for making
359 decisions. For example, the Intel Thermal Daemon can use this
360 information to allow the user to select his laptop to run without
361 turning on the fans.
362
Jacob Pan52b1c692014-09-03 15:14:23 +0800363config ACPI_THERMAL_REL
364 tristate
365 depends on ACPI
366
Tushar Daved0a12622015-06-10 13:34:24 -0700367config INTEL_PCH_THERMAL
368 tristate "Intel PCH Thermal Reporting Driver"
369 depends on X86 && PCI
370 help
371 Enable this to support thermal reporting on certain intel PCHs.
372 Thermal reporting device will provide temperature reading,
373 programmable trip points and other information.
374
Sascha Hauera92db1c2015-11-30 12:42:32 +0100375config MTK_THERMAL
376 tristate "Temperature sensor driver for mediatek SoCs"
377 depends on ARCH_MEDIATEK || COMPILE_TEST
Eduardo Valentin74e50532016-03-08 13:32:48 -0800378 depends on HAS_IOMEM
Sascha Hauera92db1c2015-11-30 12:42:32 +0100379 default y
380 help
381 Enable this option if you want to have support for thermal management
382 controller present in Mediatek SoCs
383
Eduardo Valentineb982002013-05-15 15:46:00 +0000384menu "Texas Instruments thermal drivers"
Eduardo Valentinec2feb42015-09-09 21:13:41 -0700385depends on ARCH_HAS_BANDGAP || COMPILE_TEST
Krzysztof Kozlowskibf82c352016-03-04 10:03:59 +0900386depends on HAS_IOMEM
Eduardo Valentineb982002013-05-15 15:46:00 +0000387source "drivers/thermal/ti-soc-thermal/Kconfig"
388endmenu
Zhang Ruif157f592013-06-18 06:31:26 +0800389
Amit Daniel Kachhapc6821372013-06-24 16:20:22 +0530390menu "Samsung thermal drivers"
Eduardo Valentin2bf42732015-09-09 20:53:35 -0700391depends on ARCH_EXYNOS || COMPILE_TEST
Amit Daniel Kachhapc6821372013-06-24 16:20:22 +0530392source "drivers/thermal/samsung/Kconfig"
393endmenu
394
Lee Jones60aef7c2014-06-05 16:06:55 +0100395menu "STMicroelectronics thermal drivers"
396depends on ARCH_STI && OF
397source "drivers/thermal/st/Kconfig"
398endmenu
399
Ivan T. Ivanovc610afa2015-02-05 19:12:56 +0200400config QCOM_SPMI_TEMP_ALARM
401 tristate "Qualcomm SPMI PMIC Temperature Alarm"
Arnd Bergmanne4217462015-11-16 22:43:50 +0100402 depends on OF && SPMI && IIO
Ivan T. Ivanovc610afa2015-02-05 19:12:56 +0200403 select REGMAP_SPMI
404 help
405 This enables a thermal sysfs driver for Qualcomm plug-and-play (QPNP)
406 PMIC devices. It shows up in sysfs as a thermal sensor with multiple
407 trip points. The temperature reported by the thermal sensor reflects the
408 real time die temperature if an ADC is present or an estimate of the
409 temperature based upon the over temperature stage value.
410