Guenter Roeck | 0c0a061 | 2011-03-08 22:01:39 -0800 | [diff] [blame] | 1 | Kernel driver ucd9000 |
| 2 | ===================== |
| 3 | |
| 4 | Supported chips: |
| 5 | * TI UCD90120, UCD90124, UCD9090, and UCD90910 |
| 6 | Prefixes: 'ucd90120', 'ucd90124', 'ucd9090', 'ucd90910' |
| 7 | Addresses scanned: - |
| 8 | Datasheets: |
| 9 | http://focus.ti.com/lit/ds/symlink/ucd90120.pdf |
| 10 | http://focus.ti.com/lit/ds/symlink/ucd90124.pdf |
| 11 | http://focus.ti.com/lit/ds/symlink/ucd9090.pdf |
| 12 | http://focus.ti.com/lit/ds/symlink/ucd90910.pdf |
| 13 | |
| 14 | Author: Guenter Roeck <guenter.roeck@ericsson.com> |
| 15 | |
| 16 | |
| 17 | Description |
| 18 | ----------- |
| 19 | |
| 20 | From datasheets: |
| 21 | |
| 22 | The UCD90120 Power Supply Sequencer and System Health Monitor monitors and |
| 23 | sequences up to 12 independent voltage rails. The device integrates a 12-bit |
| 24 | ADC with a 2.5V internal reference for monitoring up to 13 power supply voltage, |
| 25 | current, or temperature inputs. |
| 26 | |
| 27 | The UCD90124 is a 12-rail PMBus/I2C addressable power-supply sequencer and |
| 28 | system-health monitor. The device integrates a 12-bit ADC for monitoring up to |
| 29 | 13 power-supply voltage, current, or temperature inputs. Twenty-six GPIO pins |
| 30 | can be used for power supply enables, power-on reset signals, external |
| 31 | interrupts, cascading, or other system functions. Twelve of these pins offer PWM |
| 32 | functionality. Using these pins, the UCD90124 offers support for fan control, |
| 33 | margining, and general-purpose PWM functions. |
| 34 | |
| 35 | The UCD9090 is a 10-rail PMBus/I2C addressable power-supply sequencer and |
| 36 | monitor. The device integrates a 12-bit ADC for monitoring up to 10 power-supply |
| 37 | voltage inputs. Twenty-three GPIO pins can be used for power supply enables, |
| 38 | power-on reset signals, external interrupts, cascading, or other system |
| 39 | functions. Ten of these pins offer PWM functionality. Using these pins, the |
| 40 | UCD9090 offers support for margining, and general-purpose PWM functions. |
| 41 | |
| 42 | The UCD90910 is a ten-rail I2C / PMBus addressable power-supply sequencer and |
| 43 | system-health monitor. The device integrates a 12-bit ADC for monitoring up to |
| 44 | 13 power-supply voltage, current, or temperature inputs. |
| 45 | |
| 46 | This driver is a client driver to the core PMBus driver. Please see |
| 47 | Documentation/hwmon/pmbus for details on PMBus client drivers. |
| 48 | |
| 49 | |
| 50 | Usage Notes |
| 51 | ----------- |
| 52 | |
| 53 | This driver does not auto-detect devices. You will have to instantiate the |
| 54 | devices explicitly. Please see Documentation/i2c/instantiating-devices for |
| 55 | details. |
| 56 | |
| 57 | |
| 58 | Platform data support |
| 59 | --------------------- |
| 60 | |
| 61 | The driver supports standard PMBus driver platform data. Please see |
| 62 | Documentation/hwmon/pmbus for details. |
| 63 | |
| 64 | |
| 65 | Sysfs entries |
| 66 | ------------- |
| 67 | |
| 68 | The following attributes are supported. Limits are read-write; all other |
| 69 | attributes are read-only. |
| 70 | |
| 71 | in[1-12]_label "vout[1-12]". |
| 72 | in[1-12]_input Measured voltage. From READ_VOUT register. |
Masanari Iida | 40e4712 | 2012-03-04 23:16:11 +0900 | [diff] [blame] | 73 | in[1-12]_min Minimum Voltage. From VOUT_UV_WARN_LIMIT register. |
Guenter Roeck | 0c0a061 | 2011-03-08 22:01:39 -0800 | [diff] [blame] | 74 | in[1-12]_max Maximum voltage. From VOUT_OV_WARN_LIMIT register. |
Masanari Iida | 40e4712 | 2012-03-04 23:16:11 +0900 | [diff] [blame] | 75 | in[1-12]_lcrit Critical minimum Voltage. VOUT_UV_FAULT_LIMIT register. |
Guenter Roeck | 0c0a061 | 2011-03-08 22:01:39 -0800 | [diff] [blame] | 76 | in[1-12]_crit Critical maximum voltage. From VOUT_OV_FAULT_LIMIT register. |
| 77 | in[1-12]_min_alarm Voltage low alarm. From VOLTAGE_UV_WARNING status. |
| 78 | in[1-12]_max_alarm Voltage high alarm. From VOLTAGE_OV_WARNING status. |
| 79 | in[1-12]_lcrit_alarm Voltage critical low alarm. From VOLTAGE_UV_FAULT status. |
| 80 | in[1-12]_crit_alarm Voltage critical high alarm. From VOLTAGE_OV_FAULT status. |
| 81 | |
| 82 | curr[1-12]_label "iout[1-12]". |
| 83 | curr[1-12]_input Measured current. From READ_IOUT register. |
| 84 | curr[1-12]_max Maximum current. From IOUT_OC_WARN_LIMIT register. |
Masanari Iida | 40e4712 | 2012-03-04 23:16:11 +0900 | [diff] [blame] | 85 | curr[1-12]_lcrit Critical minimum output current. From IOUT_UC_FAULT_LIMIT |
Guenter Roeck | 0c0a061 | 2011-03-08 22:01:39 -0800 | [diff] [blame] | 86 | register. |
| 87 | curr[1-12]_crit Critical maximum current. From IOUT_OC_FAULT_LIMIT register. |
| 88 | curr[1-12]_max_alarm Current high alarm. From IOUT_OC_WARNING status. |
| 89 | curr[1-12]_crit_alarm Current critical high alarm. From IOUT_OC_FAULT status. |
| 90 | |
| 91 | For each attribute index, either voltage or current is |
| 92 | reported, but not both. If voltage or current is |
| 93 | reported depends on the chip configuration. |
| 94 | |
| 95 | temp[1-2]_input Measured temperatures. From READ_TEMPERATURE_1 and |
| 96 | READ_TEMPERATURE_2 registers. |
| 97 | temp[1-2]_max Maximum temperature. From OT_WARN_LIMIT register. |
| 98 | temp[1-2]_crit Critical high temperature. From OT_FAULT_LIMIT register. |
| 99 | temp[1-2]_max_alarm Temperature high alarm. |
| 100 | temp[1-2]_crit_alarm Temperature critical high alarm. |
| 101 | |
| 102 | fan[1-4]_input Fan RPM. |
| 103 | fan[1-4]_alarm Fan alarm. |
| 104 | fan[1-4]_fault Fan fault. |
| 105 | |
| 106 | Fan attributes are only available on chips supporting |
| 107 | fan control (UCD90124, UCD90910). Attribute files are |
| 108 | created only for enabled fans. |
| 109 | Note that even though UCD90910 supports up to 10 fans, |
| 110 | only up to four fans are currently supported. |