staging: lustre: client: Fix mkdir -i 1 from DNE2 client to DNE1 server

After DNE phase 2 has been added to client it sends
create request to slave MDT.  DNT1-only server doesn't
expect request to slave MDT from client. It expects
only cross-mdt request from master MDT. Thus if DNE2
client tries to "mkdir -i 1" on DNE1 server, then
LBUG happened.

This patch adds OBD_CONNECT_DIR_STRIPE connection
flag check on client side. If striped directories are not
supported by server, then create requrest is sent to
master MDT.

Signed-off-by: Artem Blagodarenko <artem_blagodarenko@xyratex.com>
Intel-bug-id: https://jira.hpdd.intel.com/browse/LU-6071
Xyratex-bug-id: MRP-2319
Reviewed-on: http://review.whamcloud.com/13189
Reviewed-by: Andreas Dilger <andreas.dilger@intel.com>
Reviewed-by: wang di <di.wang@intel.com>
Reviewed-by: Oleg Drokin <oleg.drokin@intel.com>
Signed-off-by: James Simmons <jsimmons@infradead.org>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
1 file changed