| # |
| # Generic thermal sysfs drivers configuration |
| # |
| |
| menuconfig THERMAL |
| tristate "Generic Thermal sysfs driver" |
| help |
| Generic Thermal Sysfs driver offers a generic mechanism for |
| thermal management. Usually it's made up of one or more thermal |
| zone and cooling device. |
| Each thermal zone contains its own temperature, trip points, |
| cooling devices. |
| All platforms with ACPI thermal support can use this driver. |
| If you want this support, you should say Y or M here. |
| |
| if THERMAL |
| |
| config THERMAL_HWMON |
| bool |
| prompt "Expose thermal sensors as hwmon device" |
| depends on HWMON=y || HWMON=THERMAL |
| default y |
| help |
| In case a sensor is registered with the thermal |
| framework, this option will also register it |
| as a hwmon. The sensor will then have the common |
| hwmon sysfs interface. |
| |
| Say 'Y' here if you want all thermal sensors to |
| have hwmon sysfs interface too. |
| |
| config THERMAL_OF |
| bool |
| prompt "APIs to parse thermal data out of device tree" |
| depends on OF |
| default y |
| help |
| This options provides helpers to add the support to |
| read and parse thermal data definitions out of the |
| device tree blob. |
| |
| Say 'Y' here if you need to build thermal infrastructure |
| based on device tree. |
| |
| choice |
| prompt "Default Thermal governor" |
| default THERMAL_DEFAULT_GOV_STEP_WISE |
| help |
| This option sets which thermal governor shall be loaded at |
| startup. If in doubt, select 'step_wise'. |
| |
| config THERMAL_DEFAULT_GOV_STEP_WISE |
| bool "step_wise" |
| select THERMAL_GOV_STEP_WISE |
| help |
| Use the step_wise governor as default. This throttles the |
| devices one step at a time. |
| |
| config THERMAL_DEFAULT_GOV_FAIR_SHARE |
| bool "fair_share" |
| select THERMAL_GOV_FAIR_SHARE |
| help |
| Use the fair_share governor as default. This throttles the |
| devices based on their 'contribution' to a zone. The |
| contribution should be provided through platform data. |
| |
| config THERMAL_DEFAULT_GOV_USER_SPACE |
| bool "user_space" |
| select THERMAL_GOV_USER_SPACE |
| help |
| Select this if you want to let the user space manage the |
| platform thermals. |
| |
| endchoice |
| |
| config THERMAL_GOV_FAIR_SHARE |
| bool "Fair-share thermal governor" |
| help |
| Enable this to manage platform thermals using fair-share governor. |
| |
| config THERMAL_GOV_STEP_WISE |
| bool "Step_wise thermal governor" |
| help |
| Enable this to manage platform thermals using a simple linear |
| governor. |
| |
| config THERMAL_GOV_USER_SPACE |
| bool "User_space thermal governor" |
| help |
| Enable this to let the user space manage the platform thermals. |
| |
| config CPU_THERMAL |
| bool "generic cpu cooling support" |
| depends on CPU_FREQ |
| depends on THERMAL_OF |
| help |
| This implements the generic cpu cooling mechanism through frequency |
| reduction. An ACPI version of this already exists |
| (drivers/acpi/processor_thermal.c). |
| This will be useful for platforms using the generic thermal interface |
| and not the ACPI interface. |
| |
| If you want this support, you should say Y here. |
| |
| config THERMAL_EMULATION |
| bool "Thermal emulation mode support" |
| help |
| Enable this option to make a emul_temp sysfs node in thermal zone |
| directory to support temperature emulation. With emulation sysfs node, |
| user can manually input temperature and test the different trip |
| threshold behaviour for simulation purpose. |
| |
| WARNING: Be careful while enabling this option on production systems, |
| because userland can easily disable the thermal policy by simply |
| flooding this sysfs node with low temperature values. |
| |
| config IMX_THERMAL |
| tristate "Temperature sensor driver for Freescale i.MX SoCs" |
| depends on CPU_THERMAL |
| depends on MFD_SYSCON |
| depends on OF |
| help |
| Support for Temperature Monitor (TEMPMON) found on Freescale i.MX SoCs. |
| It supports one critical trip point and one passive trip point. The |
| cpufreq is used as the cooling device to throttle CPUs when the |
| passive trip is crossed. |
| |
| config SPEAR_THERMAL |
| bool "SPEAr thermal sensor driver" |
| depends on PLAT_SPEAR |
| depends on OF |
| help |
| Enable this to plug the SPEAr thermal sensor driver into the Linux |
| thermal framework. |
| |
| config RCAR_THERMAL |
| tristate "Renesas R-Car thermal driver" |
| depends on ARCH_SHMOBILE || COMPILE_TEST |
| depends on HAS_IOMEM |
| help |
| Enable this to plug the R-Car thermal sensor driver into the Linux |
| thermal framework. |
| |
| config KIRKWOOD_THERMAL |
| tristate "Temperature sensor on Marvell Kirkwood SoCs" |
| depends on ARCH_KIRKWOOD |
| depends on OF |
| help |
| Support for the Kirkwood thermal sensor driver into the Linux thermal |
| framework. Only kirkwood 88F6282 and 88F6283 have this sensor. |
| |
| config DOVE_THERMAL |
| tristate "Temperature sensor on Marvell Dove SoCs" |
| depends on ARCH_DOVE |
| depends on OF |
| help |
| Support for the Dove thermal sensor driver in the Linux thermal |
| framework. |
| |
| config DB8500_THERMAL |
| bool "DB8500 thermal management" |
| depends on ARCH_U8500 |
| default y |
| help |
| Adds DB8500 thermal management implementation according to the thermal |
| management framework. A thermal zone with several trip points will be |
| created. Cooling devices can be bound to the trip points to cool this |
| thermal zone if trip points reached. |
| |
| config ARMADA_THERMAL |
| tristate "Armada 370/XP thermal management" |
| depends on ARCH_MVEBU |
| depends on OF |
| help |
| Enable this option if you want to have support for thermal management |
| controller present in Armada 370 and Armada XP SoC. |
| |
| config DB8500_CPUFREQ_COOLING |
| tristate "DB8500 cpufreq cooling" |
| depends on ARCH_U8500 |
| depends on CPU_THERMAL |
| default y |
| help |
| Adds DB8500 cpufreq cooling devices, and these cooling devices can be |
| bound to thermal zone trip points. When a trip point reached, the |
| bound cpufreq cooling device turns active to set CPU frequency low to |
| cool down the CPU. |
| |
| config INTEL_POWERCLAMP |
| tristate "Intel PowerClamp idle injection driver" |
| depends on THERMAL |
| depends on X86 |
| depends on CPU_SUP_INTEL |
| help |
| Enable this to enable Intel PowerClamp idle injection driver. This |
| enforce idle time which results in more package C-state residency. The |
| user interface is exposed via generic thermal framework. |
| |
| config X86_PKG_TEMP_THERMAL |
| tristate "X86 package temperature thermal driver" |
| depends on X86_THERMAL_VECTOR |
| select THERMAL_GOV_USER_SPACE |
| default m |
| help |
| Enable this to register CPU digital sensor for package temperature as |
| thermal zone. Each package will have its own thermal zone. There are |
| two trip points which can be set by user to get notifications via thermal |
| notification methods. |
| |
| config ACPI_INT3403_THERMAL |
| tristate "ACPI INT3403 thermal driver" |
| depends on X86 && ACPI |
| help |
| Newer laptops and tablets that use ACPI may have thermal sensors |
| outside the core CPU/SOC for thermal safety reasons. These |
| temperature sensors are also exposed for the OS to use via the so |
| called INT3403 ACPI object. This driver will, on devices that have |
| such sensors, expose the temperature information from these sensors |
| to userspace via the normal thermal framework. This means that a wide |
| range of applications and GUI widgets can show this information to |
| the user or use this information for making decisions. For example, |
| the Intel Thermal Daemon can use this information to allow the user |
| to select his laptop to run without turning on the fans. |
| |
| menu "Texas Instruments thermal drivers" |
| source "drivers/thermal/ti-soc-thermal/Kconfig" |
| endmenu |
| |
| menu "Samsung thermal drivers" |
| depends on PLAT_SAMSUNG |
| source "drivers/thermal/samsung/Kconfig" |
| endmenu |
| |
| endif |