e1000: fix VR powerdown code
On ich systems during PHY power down to D3, the voltage regulators
were left on.
Signed-off-by: Auke Kok <auke-jan.h.kok@intel.com>
Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>
diff --git a/drivers/net/e1000/e1000_hw.c b/drivers/net/e1000/e1000_hw.c
index 29e6f6a..0e2ccf5 100644
--- a/drivers/net/e1000/e1000_hw.c
+++ b/drivers/net/e1000/e1000_hw.c
@@ -3942,14 +3942,15 @@
E1000_WRITE_REG(hw, PHY_CTRL, reg | E1000_PHY_CTRL_GBE_DISABLE |
E1000_PHY_CTRL_NOND0A_GBE_DISABLE);
- /* Write VR power-down enable */
+ /* Write VR power-down enable - bits 9:8 should be 10b */
e1000_read_phy_reg(hw, IGP3_VR_CTRL, &phy_data);
- e1000_write_phy_reg(hw, IGP3_VR_CTRL, phy_data |
- IGP3_VR_CTRL_MODE_SHUT);
+ phy_data |= (1 << 9);
+ phy_data &= ~(1 << 8);
+ e1000_write_phy_reg(hw, IGP3_VR_CTRL, phy_data);
/* Read it back and test */
e1000_read_phy_reg(hw, IGP3_VR_CTRL, &phy_data);
- if ((phy_data & IGP3_VR_CTRL_MODE_SHUT) || retry)
+ if (((phy_data & IGP3_VR_CTRL_MODE_MASK) == IGP3_VR_CTRL_MODE_SHUT) || retry)
break;
/* Issue PHY reset and repeat at most one more time */