iio: si7020: Swap data byte order
The Silicon Labs Si7013, Si7020, and Si7021 family of I2C humidity and
temperature sensors deliver 16 bit data high byte first.
See the datasheet available at:
https://www.silabs.com/Support%20Documents%2fTechnicalDocs%2fSi7020-A20.pdf
But as documented in Documentation/i2c/smbus-protocol,
i2c_smbus_read_word_data() expects the low byte first.
Change the driver to use i2c_smbus_read_word_swapped to get correct byte
order.
Signed-off-by: Chris Lesiak <chris.lesiak@licor.com>
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
diff --git a/drivers/iio/humidity/si7020.c b/drivers/iio/humidity/si7020.c
index fa3b809..1b6935d 100644
--- a/drivers/iio/humidity/si7020.c
+++ b/drivers/iio/humidity/si7020.c
@@ -50,10 +50,10 @@
switch (mask) {
case IIO_CHAN_INFO_RAW:
- ret = i2c_smbus_read_word_data(*client,
- chan->type == IIO_TEMP ?
- SI7020CMD_TEMP_HOLD :
- SI7020CMD_RH_HOLD);
+ ret = i2c_smbus_read_word_swapped(*client,
+ chan->type == IIO_TEMP ?
+ SI7020CMD_TEMP_HOLD :
+ SI7020CMD_RH_HOLD);
if (ret < 0)
return ret;
*val = ret >> 2;