clk: tegra: fix vi_sensor clocks on Tegra124
vi_sensor and vi_sensor2 have a wrong hw clkid on Tegra124. Fix this by
correcting the hw clkid for Tegra124 and creating the Tegra114 vi_sensor clock
from its own data. Tegra124 was also using the wrong internal clock id.
Signed-off-by: Peter De Schrijver <pdeschrijver@nvidia.com>
diff --git a/drivers/clk/tegra/clk-tegra124.c b/drivers/clk/tegra/clk-tegra124.c
index 80efe51..d78bcb7 100644
--- a/drivers/clk/tegra/clk-tegra124.c
+++ b/drivers/clk/tegra/clk-tegra124.c
@@ -869,7 +869,7 @@
[tegra_clk_spdif_in] = { .dt_id = TEGRA124_CLK_SPDIF_IN, .present = true },
[tegra_clk_spdif_out] = { .dt_id = TEGRA124_CLK_SPDIF_OUT, .present = true },
[tegra_clk_vi_9] = { .dt_id = TEGRA124_CLK_VI, .present = true },
- [tegra_clk_vi_sensor] = { .dt_id = TEGRA124_CLK_VI_SENSOR, .present = true },
+ [tegra_clk_vi_sensor_8] = { .dt_id = TEGRA124_CLK_VI_SENSOR, .present = true },
[tegra_clk_fuse] = { .dt_id = TEGRA124_CLK_FUSE, .present = true },
[tegra_clk_fuse_burn] = { .dt_id = TEGRA124_CLK_FUSE_BURN, .present = true },
[tegra_clk_clk_32k] = { .dt_id = TEGRA124_CLK_CLK_32K, .present = true },