thermal/drivers/hisi: Simplify the temperature/step computation
commit 48880b979cdc9ef5a70af020f42b8ba1e51dbd34 upstream.
The step and the base temperature are fixed values, we can simplify the
computation by converting the base temperature to milli celsius and use a
pre-computed step value. That saves us a lot of mult + div for nothing at
runtime.
Take also the opportunity to change the function names to be consistent with
the rest of the code.
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Reviewed-by: Leo Yan <leo.yan@linaro.org>
Tested-by: Leo Yan <leo.yan@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
Signed-off-by: Kevin Wangtao <kevin.wangtao@hisilicon.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>