[ALSA] oxygen: fix AK4396 double rate upper limit
Fix the upper sample rate limit for the double rate mode of the AK4396
to the value from the datasheet.
Signed-off-by: Clemens Ladisch <clemens@ladisch.de>
Signed-off-by: Jaroslav Kysela <perex@perex.cz>
diff --git a/sound/pci/oxygen/hifier.c b/sound/pci/oxygen/hifier.c
index 05ea2b6..51c4d1a 100644
--- a/sound/pci/oxygen/hifier.c
+++ b/sound/pci/oxygen/hifier.c
@@ -90,7 +90,7 @@
value = data->ak4396_ctl2 & ~AK4396_DFS_MASK;
if (params_rate(params) <= 54000)
value |= AK4396_DFS_NORMAL;
- else if (params_rate(params) < 120000)
+ else if (params_rate(params) <= 108000)
value |= AK4396_DFS_DOUBLE;
else
value |= AK4396_DFS_QUAD;
diff --git a/sound/pci/oxygen/oxygen.c b/sound/pci/oxygen/oxygen.c
index a0457a5..840e4a6 100644
--- a/sound/pci/oxygen/oxygen.c
+++ b/sound/pci/oxygen/oxygen.c
@@ -206,7 +206,7 @@
value = data->ak4396_ctl2 & ~AK4396_DFS_MASK;
if (params_rate(params) <= 54000)
value |= AK4396_DFS_NORMAL;
- else if (params_rate(params) < 120000)
+ else if (params_rate(params) <= 108000)
value |= AK4396_DFS_DOUBLE;
else
value |= AK4396_DFS_QUAD;