[S390] qdio_get_micros return value.

qdio_get_micros is supposed to return microseconds. The get_clock()
return value needs to be shifted by 12 to get to microseconds.

Signed-off-by: Frank Pavlic <fpavlic@de.ibm.com>
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
diff --git a/drivers/s390/cio/qdio.c b/drivers/s390/cio/qdio.c
index 7c93a87..16e3715d 100644
--- a/drivers/s390/cio/qdio.c
+++ b/drivers/s390/cio/qdio.c
@@ -115,7 +115,7 @@
 static inline __u64 
 qdio_get_micros(void)
 {
-        return (get_clock() >> 10); /* time>>12 is microseconds */
+	return (get_clock() >> 12); /* time>>12 is microseconds */
 }
 
 /*