ARM: S3C24XX: enable usage of common dclk if common clock framework is enabled
Add platform device and select the correct implementation automatically
depending on wether the old samsung_clock or the common clock framework
is enabled.
This is only done for machines already using the old dclk implementation,
as everybody else should move to use dt anyway.
The machine-specific settings for the external clocks will have to be set
by somebody with knowledge about the specific hardware.
Signed-off-by: Heiko Stuebner <heiko@sntech.de>
Reviewed-by: Tomasz Figa <t.figa@samsung.com>
[pebolle@tiscali.nl: pointed out typo and fixed]
Signed-off-by: Kukjin Kim <kgene.kim@samsung.com>
diff --git a/arch/arm/mach-s3c24xx/Kconfig b/arch/arm/mach-s3c24xx/Kconfig
index fbafb9a..c9378806 100644
--- a/arch/arm/mach-s3c24xx/Kconfig
+++ b/arch/arm/mach-s3c24xx/Kconfig
@@ -18,6 +18,13 @@
help
Base platform code for any Samsung S3C24XX device
+config S3C2410_COMMON_DCLK
+ bool
+ select REGMAP_MMIO
+ help
+ Temporary symbol to build the dclk driver based on the common clock
+ framework.
+
menu "SAMSUNG S3C24XX SoCs Support"
comment "S3C24XX SoCs"
@@ -263,8 +270,9 @@
bool "Simtec Electronics BAST (EB2410ITX)"
select ISA
select MACH_BAST_IDE
+ select S3C2410_COMMON_DCLK if COMMON_CLK
select S3C2410_IOTIMING if ARM_S3C2410_CPUFREQ
- select S3C24XX_DCLK
+ select S3C24XX_DCLK if SAMSUNG_CLOCK
select S3C24XX_SIMTEC_NOR
select S3C24XX_SIMTEC_PM if PM
select S3C24XX_SIMTEC_USB
@@ -345,7 +353,8 @@
config MACH_VR1000
bool "Thorcom VR1000"
select MACH_BAST_IDE
- select S3C24XX_DCLK
+ select S3C2410_COMMON_DCLK if COMMON_CLK
+ select S3C24XX_DCLK if SAMSUNG_CLOCK
select S3C24XX_SIMTEC_NOR
select S3C24XX_SIMTEC_PM if PM
select S3C24XX_SIMTEC_USB
@@ -529,8 +538,9 @@
config MACH_ANUBIS
bool "Simtec Electronics ANUBIS"
select HAVE_PATA_PLATFORM
+ select S3C2410_COMMON_DCLK if COMMON_CLK
select S3C2440_XTAL_12000000
- select S3C24XX_DCLK
+ select S3C24XX_DCLK if SAMSUNG_CLOCK
select S3C24XX_SIMTEC_PM if PM
select S3C_DEV_USB_HOST
help
@@ -568,9 +578,10 @@
config MACH_OSIRIS
bool "Simtec IM2440D20 (OSIRIS) module"
+ select S3C2410_COMMON_DCLK if COMMON_CLK
select S3C2410_IOTIMING if ARM_S3C2440_CPUFREQ
select S3C2440_XTAL_12000000
- select S3C24XX_DCLK
+ select S3C24XX_DCLK if SAMSUNG_CLOCK
select S3C24XX_SIMTEC_PM if PM
select S3C_DEV_NAND
select S3C_DEV_USB_HOST
@@ -639,9 +650,10 @@
bool "HP iPAQ rx1950"
select I2C
select PM_H1940 if PM
+ select S3C2410_COMMON_DCLK if COMMON_CLK
select S3C2410_IOTIMING if ARM_S3C2440_CPUFREQ
select S3C2440_XTAL_16934400
- select S3C24XX_DCLK
+ select S3C24XX_DCLK if SAMSUNG_CLOCK
select S3C24XX_PWM
select S3C_DEV_NAND
help