regulator: palmas: configure enable time for LDOs

As per datasheet (Referred TPS65913), the on-time for LDO is
500micro second. If LDO6 is in vibrator mode then the on-time
is 2000us.

Set the enable_time on regulator descriptor accordingly.

Signed-off-by: Laxman Dewangan <ldewangan@nvidia.com>
Signed-off-by: Mark Brown <broonie@linaro.org>
diff --git a/drivers/regulator/palmas-regulator.c b/drivers/regulator/palmas-regulator.c
index 3c08e1b..76ce09c 100644
--- a/drivers/regulator/palmas-regulator.c
+++ b/drivers/regulator/palmas-regulator.c
@@ -1127,6 +1127,7 @@
 			pmic->desc[id].min_uV = 900000;
 			pmic->desc[id].uV_step = 50000;
 			pmic->desc[id].linear_min_sel = 1;
+			pmic->desc[id].enable_time = 500;
 			pmic->desc[id].vsel_reg =
 					PALMAS_BASE_TO_REG(PALMAS_LDO_BASE,
 						palmas_regs_info[id].vsel_addr);
@@ -1145,6 +1146,11 @@
 				pmic->desc[id].min_uV = 450000;
 				pmic->desc[id].uV_step = 25000;
 			}
+
+			/* LOD6 in vibrator mode will have enable time 2000us */
+			if (pdata && pdata->ldo6_vibrator &&
+				(id == PALMAS_REG_LDO6))
+				pmic->desc[id].enable_time = 2000;
 		} else {
 			pmic->desc[id].n_voltages = 1;
 			if (reg_init && reg_init->roof_floor)