greybus: svc: Set interface's hotplug attributes before using them

gb_svc_read_and_clear_module_boot_status() relies on the values of
ddbl1_manufacturer_id and ddbl1_product_id to distinguish between ES2
and ES3 chips, but those values are set for the interface structure only
after gb_svc_read_and_clear_module_boot_status() is called.

This makes ES2 module to fail with following errors:

greybus 1-2: Module not ready yet
greybus 1-svc: failed to clear boot status of interface 2: -19

Fix this by setting these values before calling
gb_svc_read_and_clear_module_boot_status().

Fixes: 51f1dc421b1f ("firmware and svc: detect the difference between ES2 and ES3 chips")
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Reviewed-by: Johan Hovold <johan@hovoldconsulting.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@google.com>
diff --git a/drivers/staging/greybus/svc.c b/drivers/staging/greybus/svc.c
index 3e760e6..4178699 100644
--- a/drivers/staging/greybus/svc.c
+++ b/drivers/staging/greybus/svc.c
@@ -425,6 +425,11 @@
 		return;
 	}
 
+	intf->ddbl1_manufacturer_id = le32_to_cpu(request->data.ddbl1_mfr_id);
+	intf->ddbl1_product_id = le32_to_cpu(request->data.ddbl1_prod_id);
+	intf->vendor_id = le32_to_cpu(request->data.ara_vend_id);
+	intf->product_id = le32_to_cpu(request->data.ara_prod_id);
+
 	ret = gb_svc_read_and_clear_module_boot_status(intf);
 	if (ret) {
 		dev_err(&svc->dev, "failed to clear boot status of interface %u: %d\n",
@@ -432,11 +437,6 @@
 		goto destroy_interface;
 	}
 
-	intf->ddbl1_manufacturer_id = le32_to_cpu(request->data.ddbl1_mfr_id);
-	intf->ddbl1_product_id = le32_to_cpu(request->data.ddbl1_prod_id);
-	intf->vendor_id = le32_to_cpu(request->data.ara_vend_id);
-	intf->product_id = le32_to_cpu(request->data.ara_prod_id);
-
 	/*
 	 * Create a device id for the interface:
 	 * - device id 0 (GB_DEVICE_ID_SVC) belongs to the SVC