scsi: ufs: fix error handing during hibern8 enter

During clock gating (ufshcd_gate_work()), we first put the link hibern8 by
calling ufshcd_uic_hibern8_enter() and if ufshcd_uic_hibern8_enter()
returns success (0) then we gate all the clocks.
Now let’s zoom in to what ufshcd_uic_hibern8_enter() does internally:
It calls __ufshcd_uic_hibern8_enter() which on detecting the LINERESET,
initiates the full recovery and puts the link back to highest HS gear and
returns success (0) to ufshcd_uic_hibern8_enter() which is the issue as
link is still in active state due to recovery!
Now ufshcd_uic_hibern8_enter() returns success to ufshcd_gate_work() and
hence it goes ahead with gating the UFS clock while link is still in active
state hence I believe controller would raise UIC error interrupts. But when
we service the interrupt, clocks might have already been disabled!

This change fixes for this by returning failure from
__ufshcd_uic_hibern8_enter() if recovery succeeds as link is still not in
hibern8, upon receiving the error ufshcd_hibern8_enter() would initiate
retry to put the link state back into hibern8.

Change-Id: Ib550fb791fa4c582b8f2d317a7f5f7594acb0872
Signed-off-by: Subhash Jadavani <subhashj@codeaurora.org>
1 file changed