clocksource: samsung_pwm_timer: Work around rounding errors in clockevents core
Due to rounding errors in clockevents core (in conversions between ticks
and nsecs), it might happen that the set_next_event callback gets called
with cycles = 0, causing the code to incorrectly program the PWM timer.
This patch modifies the callback to program the timer for 1 tick, if
received tick count value is 0.
Signed-off-by: Tomasz Figa <t.figa@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Reviewed-by: Arnd Bergmann <arnd@arndb.de>
Acked-by: Kukjin Kim <kgene.kim@samsung.com>
Signed-off-by: Olof Johansson <olof@lixom.net>
1 file changed