ab8500-btemp: Filter btemp readings

Battery tempreature readings sometimes fail and results in
a value far from recent values. This patch adds a software
filter that disposes such readings, by allowing direct
updates on temperature only if two samples result in the
same temperature. Else only allow 1 degree change from previous
reported value in the direction of the new measurement.

Signed-off-by: Hakan Berg <hakan.berg@stericsson.com>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Reviewed-by: Marcus COOPER <marcus.xm.cooper@stericsson.com>
Reviewed-by: Martin SJOBLOM <martin.w.sjoblom@stericsson.com>
Reviewed-by: Rabin VINCENT <rabin.vincent@stericsson.com>
1 file changed