rtc: omap: silence bogus power-up reset message at probe

Some legacy RTC IP revisions has a power-up reset flag in the status
register that later revisions lack.

As this flag is always read back as set on later revisions (or is
overloaded with a different flag), make sure to only clear the flag and
print the info message on legacy platforms.

Signed-off-by: Johan Hovold <johan@kernel.org>
Cc: Alessandro Zummo <a.zummo@towertech.it>
Cc: Tony Lindgren <tony@atomide.com>
Cc: Benot Cousson <bcousson@baylibre.com>
Cc: Lokesh Vutla <lokeshvutla@ti.com>
Cc: Guenter Roeck <linux@roeck-us.net>
Cc: Sekhar Nori <nsekhar@ti.com>
Cc: Tero Kristo <t-kristo@ti.com>
Cc: Keerthy J <j-keerthy@ti.com>
Tested-by: Felipe Balbi <balbi@ti.com>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
1 file changed