[ARM] 4052/1: S3C24XX: Fix PM in arch/arm/mach-s3c2410/Kconfig
Fix up the CONFIG_PM mixups in arch/arm/mach-s3c2410/Kconfig
causing CONFIG_S3C2410_PM and CONFIG_PM_H1940 to get enabled
permanently.
Signed-off-by: Ben Dooks <ben-linux@fluff.org>
Signed-off-by: Russell King <rmk+kernel@arm.linux.org.uk>
diff --git a/arch/arm/mach-s3c2410/Kconfig b/arch/arm/mach-s3c2410/Kconfig
index 9f46bf3..9ac6b5d 100644
--- a/arch/arm/mach-s3c2410/Kconfig
+++ b/arch/arm/mach-s3c2410/Kconfig
@@ -43,14 +43,13 @@
config PM_H1940
bool
- depends on PM
help
Internal node for H1940 and related PM
config ARCH_H1940
bool "IPAQ H1940"
select CPU_S3C2410
- select PM_H1940
+ select PM_H1940 if PM
help
Say Y here if you are using the HP IPAQ H1940
@@ -122,7 +121,7 @@
config MACH_RX3715
bool "HP iPAQ rx3715"
select CPU_S3C2440
- select PM_H1940
+ select PM_H1940 if PM
help
Say Y here if you are using the HP iPAQ rx3715.
@@ -156,7 +155,6 @@
config S3C2410_PM
bool
- depends on CONFIG_PM
help
Power Management code common to S3C2410 and better
@@ -171,7 +169,7 @@
bool
depends on ARCH_S3C2410
select S3C2410_CLOCK
- select S3C2410_PM
+ select S3C2410_PM if PM
help
Support for S3C2410 and S3C2410A family from the S3C24XX line
of Samsung Mobile CPUs.
@@ -186,14 +184,13 @@
config S3C2412_PM
bool
- default y if PM
- depends on CPU_S3C2412
help
Internal config node to apply S3C2412 power management
config CPU_S3C2412
bool
depends on ARCH_S3C2410
+ select S3C2412_PM if PM
help
Support for the S3C2412 and S3C2413 SoCs from the S3C24XX line
@@ -207,7 +204,7 @@
bool
depends on ARCH_S3C2410
select S3C2410_CLOCK
- select S3C2410_PM
+ select S3C2410_PM if PM
select CPU_S3C244X
help
Support for S3C2440 Samsung Mobile CPU based systems.
@@ -216,7 +213,7 @@
bool
depends on ARCH_S3C2420
select S3C2410_CLOCK
- select S3C2410_PM
+ select S3C2410_PM if PM
select CPU_S3C244X
help
Support for S3C2442 Samsung Mobile CPU based systems.