fs: Implement lazy LRU updates for inodes

Convert the inode LRU to use lazy updates to reduce lock and
cacheline traffic.  We avoid moving inodes around in the LRU list
during iget/iput operations so these frequent operations don't need
to access the LRUs. Instead, we defer the refcount checks to
reclaim-time and use a per-inode state flag, I_REFERENCED, to tell
reclaim that iget has touched the inode in the past. This means that
only reclaim should be touching the LRU with any frequency, hence
significantly reducing lock acquisitions and the amount contention
on LRU updates.

This also removes the inode_in_use list, which means we now only
have one list for tracking the inode LRU status. This makes it much
simpler to split out the LRU list operations under it's own lock.

Signed-off-by: Nick Piggin <npiggin@suse.de>
Signed-off-by: Dave Chinner <dchinner@redhat.com>
Reviewed-by: Christoph Hellwig <hch@lst.de>
Signed-off-by: Al Viro <viro@zeniv.linux.org.uk>
diff --git a/fs/inode.c b/fs/inode.c
index 0d5aecc..3bdc76f 100644
--- a/fs/inode.c
+++ b/fs/inode.c
@@ -72,8 +72,7 @@
  * allowing for low-overhead inode sync() operations.
  */
 
-LIST_HEAD(inode_in_use);
-LIST_HEAD(inode_unused);
+static LIST_HEAD(inode_unused);
 static struct hlist_head *inode_hashtable __read_mostly;
 
 /*
@@ -291,6 +290,7 @@
 	INIT_HLIST_NODE(&inode->i_hash);
 	INIT_LIST_HEAD(&inode->i_dentry);
 	INIT_LIST_HEAD(&inode->i_devices);
+	INIT_LIST_HEAD(&inode->i_list);
 	INIT_RADIX_TREE(&inode->i_data.page_tree, GFP_ATOMIC);
 	spin_lock_init(&inode->i_data.tree_lock);
 	spin_lock_init(&inode->i_data.i_mmap_lock);
@@ -317,12 +317,23 @@
  */
 void __iget(struct inode *inode)
 {
-	if (atomic_inc_return(&inode->i_count) != 1)
-		return;
+	atomic_inc(&inode->i_count);
+}
 
-	if (!(inode->i_state & (I_DIRTY|I_SYNC)))
-		list_move(&inode->i_list, &inode_in_use);
-	percpu_counter_dec(&nr_inodes_unused);
+static void inode_lru_list_add(struct inode *inode)
+{
+	if (list_empty(&inode->i_list)) {
+		list_add(&inode->i_list, &inode_unused);
+		percpu_counter_inc(&nr_inodes_unused);
+	}
+}
+
+static void inode_lru_list_del(struct inode *inode)
+{
+	if (!list_empty(&inode->i_list)) {
+		list_del_init(&inode->i_list);
+		percpu_counter_dec(&nr_inodes_unused);
+	}
 }
 
 void end_writeback(struct inode *inode)
@@ -367,7 +378,7 @@
 		struct inode *inode;
 
 		inode = list_first_entry(head, struct inode, i_list);
-		list_del(&inode->i_list);
+		list_del_init(&inode->i_list);
 
 		evict(inode);
 
@@ -413,7 +424,8 @@
 			list_move(&inode->i_list, dispose);
 			WARN_ON(inode->i_state & I_NEW);
 			inode->i_state |= I_FREEING;
-			percpu_counter_dec(&nr_inodes_unused);
+			if (!(inode->i_state & (I_DIRTY | I_SYNC)))
+				percpu_counter_dec(&nr_inodes_unused);
 			continue;
 		}
 		busy = 1;
@@ -448,7 +460,7 @@
 
 static int can_unuse(struct inode *inode)
 {
-	if (inode->i_state)
+	if (inode->i_state & ~I_REFERENCED)
 		return 0;
 	if (inode_has_buffers(inode))
 		return 0;
@@ -460,17 +472,20 @@
 }
 
 /*
- * Scan `goal' inodes on the unused list for freeable ones. They are moved to
- * a temporary list and then are freed outside inode_lock by dispose_list().
+ * Scan `goal' inodes on the unused list for freeable ones. They are moved to a
+ * temporary list and then are freed outside inode_lock by dispose_list().
  *
  * Any inodes which are pinned purely because of attached pagecache have their
- * pagecache removed.  We expect the final iput() on that inode to add it to
- * the front of the inode_unused list.  So look for it there and if the
- * inode is still freeable, proceed.  The right inode is found 99.9% of the
- * time in testing on a 4-way.
+ * pagecache removed.  If the inode has metadata buffers attached to
+ * mapping->private_list then try to remove them.
  *
- * If the inode has metadata buffers attached to mapping->private_list then
- * try to remove them.
+ * If the inode has the I_REFERENCED flag set, then it means that it has been
+ * used recently - the flag is set in iput_final(). When we encounter such an
+ * inode, clear the flag and move it to the back of the LRU so it gets another
+ * pass through the LRU before it gets reclaimed. This is necessary because of
+ * the fact we are doing lazy LRU updates to minimise lock contention so the
+ * LRU does not have strict ordering. Hence we don't want to reclaim inodes
+ * with this flag set because they are the inodes that are out of order.
  */
 static void prune_icache(int nr_to_scan)
 {
@@ -488,8 +503,21 @@
 
 		inode = list_entry(inode_unused.prev, struct inode, i_list);
 
-		if (inode->i_state || atomic_read(&inode->i_count)) {
+		/*
+		 * Referenced or dirty inodes are still in use. Give them
+		 * another pass through the LRU as we canot reclaim them now.
+		 */
+		if (atomic_read(&inode->i_count) ||
+		    (inode->i_state & ~I_REFERENCED)) {
+			list_del_init(&inode->i_list);
+			percpu_counter_dec(&nr_inodes_unused);
+			continue;
+		}
+
+		/* recently referenced inodes get one more pass */
+		if (inode->i_state & I_REFERENCED) {
 			list_move(&inode->i_list, &inode_unused);
+			inode->i_state &= ~I_REFERENCED;
 			continue;
 		}
 		if (inode_has_buffers(inode) || inode->i_data.nrpages) {
@@ -620,7 +648,6 @@
 __inode_add_to_lists(struct super_block *sb, struct hlist_head *head,
 			struct inode *inode)
 {
-	list_add(&inode->i_list, &inode_in_use);
 	list_add(&inode->i_sb_list, &sb->s_inodes);
 	if (head)
 		hlist_add_head(&inode->i_hash, head);
@@ -1237,10 +1264,11 @@
 		drop = generic_drop_inode(inode);
 
 	if (!drop) {
-		if (!(inode->i_state & (I_DIRTY|I_SYNC)))
-			list_move(&inode->i_list, &inode_unused);
-		percpu_counter_inc(&nr_inodes_unused);
 		if (sb->s_flags & MS_ACTIVE) {
+			inode->i_state |= I_REFERENCED;
+			if (!(inode->i_state & (I_DIRTY|I_SYNC))) {
+				inode_lru_list_add(inode);
+			}
 			spin_unlock(&inode_lock);
 			return;
 		}
@@ -1251,13 +1279,19 @@
 		spin_lock(&inode_lock);
 		WARN_ON(inode->i_state & I_NEW);
 		inode->i_state &= ~I_WILL_FREE;
-		percpu_counter_dec(&nr_inodes_unused);
 		hlist_del_init(&inode->i_hash);
 	}
-	list_del_init(&inode->i_list);
-	list_del_init(&inode->i_sb_list);
 	WARN_ON(inode->i_state & I_NEW);
 	inode->i_state |= I_FREEING;
+
+	/*
+	 * After we delete the inode from the LRU here, we avoid moving dirty
+	 * inodes back onto the LRU now because I_FREEING is set and hence
+	 * writeback_single_inode() won't move the inode around.
+	 */
+	inode_lru_list_del(inode);
+
+	list_del_init(&inode->i_sb_list);
 	spin_unlock(&inode_lock);
 	evict(inode);
 	spin_lock(&inode_lock);