mac80211: correctly close cancelled scans
__ieee80211_scan_completed is called from a worker. This
means that the following flow is possible.
* driver calls ieee80211_scan_completed
* mac80211 cancels the scan (that is already complete)
* __ieee80211_scan_completed runs
When scan_work will finally run, it will see that the scan
hasn't been aborted and might even trigger another scan on
another band. This leads to a situation where cfg80211's
scan is not done and no further scan can be issued.
Fix this by setting a new flag when a HW scan is being
cancelled so that no other scan will be triggered.
Cc: stable@vger.kernel.org
Signed-off-by: Emmanuel Grumbach <emmanuel.grumbach@intel.com>
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
diff --git a/net/mac80211/scan.c b/net/mac80211/scan.c
index 08afe74..d2d17a4 100644
--- a/net/mac80211/scan.c
+++ b/net/mac80211/scan.c
@@ -238,6 +238,9 @@
enum ieee80211_band band;
int i, ielen, n_chans;
+ if (test_bit(SCAN_HW_CANCELLED, &local->scanning))
+ return false;
+
do {
if (local->hw_scan_band == IEEE80211_NUM_BANDS)
return false;
@@ -940,7 +943,23 @@
if (!local->scan_req)
goto out;
+ /*
+ * We have a scan running and the driver already reported completion,
+ * but the worker hasn't run yet or is stuck on the mutex - mark it as
+ * cancelled.
+ */
+ if (test_bit(SCAN_HW_SCANNING, &local->scanning) &&
+ test_bit(SCAN_COMPLETED, &local->scanning)) {
+ set_bit(SCAN_HW_CANCELLED, &local->scanning);
+ goto out;
+ }
+
if (test_bit(SCAN_HW_SCANNING, &local->scanning)) {
+ /*
+ * Make sure that __ieee80211_scan_completed doesn't trigger a
+ * scan on another band.
+ */
+ set_bit(SCAN_HW_CANCELLED, &local->scanning);
if (local->ops->cancel_hw_scan)
drv_cancel_hw_scan(local,
rcu_dereference_protected(local->scan_sdata,