bnx2x: Common init will be executed only once after POR

Common init used to be called by the driver when the first port comes up, mainly to reset and reload external PHY microcode.
However, in case management driver is active on the other port, traffic would halted. So limit the common init to be done only once after POR.

Signed-off-by: Yaniv Rosner <yanivr@broadcom.com>
Signed-off-by: Eilon Greenstein <eilong@broadcom.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
diff --git a/drivers/net/bnx2x/bnx2x_link.c b/drivers/net/bnx2x/bnx2x_link.c
index 77f9eb19..bdf3c67 100644
--- a/drivers/net/bnx2x/bnx2x_link.c
+++ b/drivers/net/bnx2x/bnx2x_link.c
@@ -7958,6 +7958,7 @@
 			 u32 shmem2_base_path[], u32 chip_id)
 {
 	u8 rc = 0;
+	u32 phy_ver;
 	u8 phy_index;
 	u32 ext_phy_type, ext_phy_config;
 	DP(NETIF_MSG_LINK, "Begin common phy init\n");
@@ -7965,6 +7966,16 @@
 	if (CHIP_REV_IS_EMUL(bp))
 		return 0;
 
+	/* Check if common init was already done */
+	phy_ver = REG_RD(bp, shmem_base_path[0] +
+			 offsetof(struct shmem_region,
+				  port_mb[PORT_0].ext_phy_fw_version));
+	if (phy_ver) {
+		DP(NETIF_MSG_LINK, "Not doing common init; phy ver is 0x%x\n",
+			       phy_ver);
+		return 0;
+	}
+
 	/* Read the ext_phy_type for arbitrary port(0) */
 	for (phy_index = EXT_PHY1; phy_index < MAX_PHYS;
 	      phy_index++) {