power_supply: cleanup of the OLPC battery driver

Move portions of the massive switch statement into functions.  The layout of
this thing has already caused one bug (a break in the wrong place), it needed
to shrink.

Signed-off-by: Andres Salomon <dilinger@debian.org>
Cc: David Woodhouse <dwmw2@infradead.org>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
diff --git a/drivers/power/olpc_battery.c b/drivers/power/olpc_battery.c
index f8dc2b1..d5fe6f0 100644
--- a/drivers/power/olpc_battery.c
+++ b/drivers/power/olpc_battery.c
@@ -86,6 +86,117 @@
 
 static char bat_serial[17]; /* Ick */
 
+static int olpc_bat_get_status(union power_supply_propval *val, uint8_t ec_byte)
+{
+	if (olpc_platform_info.ecver > 0x44) {
+		if (ec_byte & BAT_STAT_CHARGING)
+			val->intval = POWER_SUPPLY_STATUS_CHARGING;
+		else if (ec_byte & BAT_STAT_DISCHARGING)
+			val->intval = POWER_SUPPLY_STATUS_DISCHARGING;
+		else if (ec_byte & BAT_STAT_FULL)
+			val->intval = POWER_SUPPLY_STATUS_FULL;
+		else /* er,... */
+			val->intval = POWER_SUPPLY_STATUS_NOT_CHARGING;
+	} else {
+		/* Older EC didn't report charge/discharge bits */
+		if (!(ec_byte & BAT_STAT_AC)) /* No AC means discharging */
+			val->intval = POWER_SUPPLY_STATUS_DISCHARGING;
+		else if (ec_byte & BAT_STAT_FULL)
+			val->intval = POWER_SUPPLY_STATUS_FULL;
+		else /* Not _necessarily_ true but EC doesn't tell all yet */
+			val->intval = POWER_SUPPLY_STATUS_CHARGING;
+	}
+
+	return 0;
+}
+
+static int olpc_bat_get_health(union power_supply_propval *val)
+{
+	uint8_t ec_byte;
+	int ret;
+
+	ret = olpc_ec_cmd(EC_BAT_ERRCODE, NULL, 0, &ec_byte, 1);
+	if (ret)
+		return ret;
+
+	switch (ec_byte) {
+	case 0:
+		val->intval = POWER_SUPPLY_HEALTH_GOOD;
+		break;
+
+	case BAT_ERR_OVERTEMP:
+		val->intval = POWER_SUPPLY_HEALTH_OVERHEAT;
+		break;
+
+	case BAT_ERR_OVERVOLTAGE:
+		val->intval = POWER_SUPPLY_HEALTH_OVERVOLTAGE;
+		break;
+
+	case BAT_ERR_INFOFAIL:
+	case BAT_ERR_OUT_OF_CONTROL:
+	case BAT_ERR_ID_FAIL:
+	case BAT_ERR_ACR_FAIL:
+		val->intval = POWER_SUPPLY_HEALTH_UNSPEC_FAILURE;
+		break;
+
+	default:
+		/* Eep. We don't know this failure code */
+		ret = -EIO;
+	}
+
+	return ret;
+}
+
+static int olpc_bat_get_mfr(union power_supply_propval *val)
+{
+	uint8_t ec_byte;
+	int ret;
+
+	ec_byte = BAT_ADDR_MFR_TYPE;
+	ret = olpc_ec_cmd(EC_BAT_EEPROM, &ec_byte, 1, &ec_byte, 1);
+	if (ret)
+		return ret;
+
+	switch (ec_byte >> 4) {
+	case 1:
+		val->strval = "Gold Peak";
+		break;
+	case 2:
+		val->strval = "BYD";
+		break;
+	default:
+		val->strval = "Unknown";
+		break;
+	}
+
+	return ret;
+}
+
+static int olpc_bat_get_tech(union power_supply_propval *val)
+{
+	uint8_t ec_byte;
+	int ret;
+
+	ec_byte = BAT_ADDR_MFR_TYPE;
+	ret = olpc_ec_cmd(EC_BAT_EEPROM, &ec_byte, 1, &ec_byte, 1);
+	if (ret)
+		return ret;
+
+	switch (ec_byte & 0xf) {
+	case 1:
+		val->intval = POWER_SUPPLY_TECHNOLOGY_NiMH;
+		break;
+	case 2:
+		val->intval = POWER_SUPPLY_TECHNOLOGY_LiFe;
+		break;
+	default:
+		val->intval = POWER_SUPPLY_TECHNOLOGY_UNKNOWN;
+		break;
+	}
+
+	return ret;
+}
+
 /*********************************************************************
  *		Battery properties
  *********************************************************************/
@@ -113,25 +224,10 @@
 
 	switch (psp) {
 	case POWER_SUPPLY_PROP_STATUS:
-		if (olpc_platform_info.ecver > 0x44) {
-			if (ec_byte & BAT_STAT_CHARGING)
-				val->intval = POWER_SUPPLY_STATUS_CHARGING;
-			else if (ec_byte & BAT_STAT_DISCHARGING)
-				val->intval = POWER_SUPPLY_STATUS_DISCHARGING;
-			else if (ec_byte & BAT_STAT_FULL)
-				val->intval = POWER_SUPPLY_STATUS_FULL;
-			else /* er,... */
-				val->intval = POWER_SUPPLY_STATUS_NOT_CHARGING;
-		} else {
-			/* Older EC didn't report charge/discharge bits */
-			if (!(ec_byte & BAT_STAT_AC)) /* No AC means discharging */
-				val->intval = POWER_SUPPLY_STATUS_DISCHARGING;
-			else if (ec_byte & BAT_STAT_FULL)
-				val->intval = POWER_SUPPLY_STATUS_FULL;
-			else /* Not _necessarily_ true but EC doesn't tell all yet */
-				val->intval = POWER_SUPPLY_STATUS_CHARGING;
-			break;
-		}
+		ret = olpc_bat_get_status(val, ec_byte);
+		if (ret)
+			return ret;
+		break;
 	case POWER_SUPPLY_PROP_PRESENT:
 		val->intval = !!(ec_byte & BAT_STAT_PRESENT);
 		break;
@@ -140,72 +236,21 @@
 		if (ec_byte & BAT_STAT_DESTROY)
 			val->intval = POWER_SUPPLY_HEALTH_DEAD;
 		else {
-			ret = olpc_ec_cmd(EC_BAT_ERRCODE, NULL, 0, &ec_byte, 1);
+			ret = olpc_bat_get_health(val);
 			if (ret)
 				return ret;
-
-			switch (ec_byte) {
-			case 0:
-				val->intval = POWER_SUPPLY_HEALTH_GOOD;
-				break;
-
-			case BAT_ERR_OVERTEMP:
-				val->intval = POWER_SUPPLY_HEALTH_OVERHEAT;
-				break;
-
-			case BAT_ERR_OVERVOLTAGE:
-				val->intval = POWER_SUPPLY_HEALTH_OVERVOLTAGE;
-				break;
-
-			case BAT_ERR_INFOFAIL:
-			case BAT_ERR_OUT_OF_CONTROL:
-			case BAT_ERR_ID_FAIL:
-			case BAT_ERR_ACR_FAIL:
-				val->intval = POWER_SUPPLY_HEALTH_UNSPEC_FAILURE;
-				break;
-
-			default:
-				/* Eep. We don't know this failure code */
-				return -EIO;
-			}
 		}
 		break;
 
 	case POWER_SUPPLY_PROP_MANUFACTURER:
-		ec_byte = BAT_ADDR_MFR_TYPE;
-		ret = olpc_ec_cmd(EC_BAT_EEPROM, &ec_byte, 1, &ec_byte, 1);
+		ret = olpc_bat_get_mfr(val);
 		if (ret)
 			return ret;
-
-		switch (ec_byte >> 4) {
-		case 1:
-			val->strval = "Gold Peak";
-			break;
-		case 2:
-			val->strval = "BYD";
-			break;
-		default:
-			val->strval = "Unknown";
-			break;
-		}
 		break;
 	case POWER_SUPPLY_PROP_TECHNOLOGY:
-		ec_byte = BAT_ADDR_MFR_TYPE;
-		ret = olpc_ec_cmd(EC_BAT_EEPROM, &ec_byte, 1, &ec_byte, 1);
+		ret = olpc_bat_get_tech(val);
 		if (ret)
 			return ret;
-
-		switch (ec_byte & 0xf) {
-		case 1:
-			val->intval = POWER_SUPPLY_TECHNOLOGY_NiMH;
-			break;
-		case 2:
-			val->intval = POWER_SUPPLY_TECHNOLOGY_LiFe;
-			break;
-		default:
-			val->intval = POWER_SUPPLY_TECHNOLOGY_UNKNOWN;
-			break;
-		}
 		break;
 	case POWER_SUPPLY_PROP_VOLTAGE_AVG:
 		ret = olpc_ec_cmd(EC_BAT_VOLTAGE, NULL, 0, (void *)&ec_word, 2);