power_supply: charger-manager: Use power_supply_*() API for accessing function attrs

Replace direct calls to power supply function attributes with wrappers.
Wrappers provide safe access in case of unregistering the power
supply (e.g. by removing the driver). Replace:
 - get_property -> power_supply_get_property

Signed-off-by: Krzysztof Kozlowski <k.kozlowski@samsung.com>
Acked-by: Jonghwa Lee <jonghwa3.lee@samsung.com>
Acked-by: Pavel Machek <pavel@ucw.cz>
Reviewed-by: Bartlomiej Zolnierkiewicz <b.zolnierkie@samsung.com>
Reviewed-by: Sebastian Reichel <sre@kernel.org>
Signed-off-by: Sebastian Reichel <sre@kernel.org>
diff --git a/drivers/power/charger-manager.c b/drivers/power/charger-manager.c
index df27600..a5b86b6 100644
--- a/drivers/power/charger-manager.c
+++ b/drivers/power/charger-manager.c
@@ -103,8 +103,8 @@
 		if (!psy)
 			break;
 
-		ret = psy->get_property(psy,
-				POWER_SUPPLY_PROP_PRESENT, &val);
+		ret = power_supply_get_property(psy, POWER_SUPPLY_PROP_PRESENT,
+				&val);
 		if (ret == 0 && val.intval)
 			present = true;
 		break;
@@ -118,8 +118,8 @@
 				continue;
 			}
 
-			ret = psy->get_property(psy, POWER_SUPPLY_PROP_PRESENT,
-					&val);
+			ret = power_supply_get_property(psy,
+				POWER_SUPPLY_PROP_PRESENT, &val);
 			if (ret == 0 && val.intval) {
 				present = true;
 				break;
@@ -155,7 +155,8 @@
 			continue;
 		}
 
-		ret = psy->get_property(psy, POWER_SUPPLY_PROP_ONLINE, &val);
+		ret = power_supply_get_property(psy, POWER_SUPPLY_PROP_ONLINE,
+				&val);
 		if (ret == 0 && val.intval) {
 			online = true;
 			break;
@@ -183,7 +184,7 @@
 	if (!fuel_gauge)
 		return -ENODEV;
 
-	ret = fuel_gauge->get_property(fuel_gauge,
+	ret = power_supply_get_property(fuel_gauge,
 				POWER_SUPPLY_PROP_VOLTAGE_NOW, &val);
 	if (ret)
 		return ret;
@@ -223,7 +224,8 @@
 		}
 
 		/* 2. The charger should be online (ext-power) */
-		ret = psy->get_property(psy, POWER_SUPPLY_PROP_ONLINE, &val);
+		ret = power_supply_get_property(psy, POWER_SUPPLY_PROP_ONLINE,
+				&val);
 		if (ret) {
 			dev_warn(cm->dev, "Cannot read ONLINE value from %s\n",
 				 cm->desc->psy_charger_stat[i]);
@@ -236,7 +238,8 @@
 		 * 3. The charger should not be FULL, DISCHARGING,
 		 * or NOT_CHARGING.
 		 */
-		ret = psy->get_property(psy, POWER_SUPPLY_PROP_STATUS, &val);
+		ret = power_supply_get_property(psy, POWER_SUPPLY_PROP_STATUS,
+				&val);
 		if (ret) {
 			dev_warn(cm->dev, "Cannot read STATUS value from %s\n",
 				 cm->desc->psy_charger_stat[i]);
@@ -279,7 +282,7 @@
 		val.intval = 0;
 
 		/* Not full if capacity of fuel gauge isn't full */
-		ret = fuel_gauge->get_property(fuel_gauge,
+		ret = power_supply_get_property(fuel_gauge,
 				POWER_SUPPLY_PROP_CHARGE_FULL, &val);
 		if (!ret && val.intval > desc->fullbatt_full_capacity)
 			return true;
@@ -296,7 +299,7 @@
 	if (desc->fullbatt_soc > 0) {
 		val.intval = 0;
 
-		ret = fuel_gauge->get_property(fuel_gauge,
+		ret = power_supply_get_property(fuel_gauge,
 				POWER_SUPPLY_PROP_CAPACITY, &val);
 		if (!ret && val.intval >= desc->fullbatt_soc)
 			return true;
@@ -580,7 +583,7 @@
 	if (!fuel_gauge)
 		return -ENODEV;
 
-	return fuel_gauge->get_property(fuel_gauge,
+	return power_supply_get_property(fuel_gauge,
 				POWER_SUPPLY_PROP_TEMP,
 				(union power_supply_propval *)temp);
 }
@@ -900,7 +903,7 @@
 			ret = -ENODEV;
 			break;
 		}
-		ret = fuel_gauge->get_property(fuel_gauge,
+		ret = power_supply_get_property(fuel_gauge,
 				POWER_SUPPLY_PROP_CURRENT_NOW, val);
 		break;
 	case POWER_SUPPLY_PROP_TEMP:
@@ -919,7 +922,7 @@
 			break;
 		}
 
-		ret = fuel_gauge->get_property(fuel_gauge,
+		ret = power_supply_get_property(fuel_gauge,
 					POWER_SUPPLY_PROP_CAPACITY, val);
 		if (ret)
 			break;
@@ -975,7 +978,7 @@
 				break;
 			}
 
-			ret = fuel_gauge->get_property(fuel_gauge,
+			ret = power_supply_get_property(fuel_gauge,
 						POWER_SUPPLY_PROP_CHARGE_NOW,
 						val);
 			if (ret) {
@@ -1424,7 +1427,7 @@
 	int ret;
 
 	/* Verify whether fuel gauge provides battery temperature */
-	ret = fuel_gauge->get_property(fuel_gauge,
+	ret = power_supply_get_property(fuel_gauge,
 					POWER_SUPPLY_PROP_TEMP, &val);
 
 	if (!ret) {
@@ -1718,13 +1721,13 @@
 	cm->charger_psy.num_properties = psy_default.num_properties;
 
 	/* Find which optional psy-properties are available */
-	if (!fuel_gauge->get_property(fuel_gauge,
+	if (!power_supply_get_property(fuel_gauge,
 					  POWER_SUPPLY_PROP_CHARGE_NOW, &val)) {
 		cm->charger_psy.properties[cm->charger_psy.num_properties] =
 				POWER_SUPPLY_PROP_CHARGE_NOW;
 		cm->charger_psy.num_properties++;
 	}
-	if (!fuel_gauge->get_property(fuel_gauge,
+	if (!power_supply_get_property(fuel_gauge,
 					  POWER_SUPPLY_PROP_CURRENT_NOW,
 					  &val)) {
 		cm->charger_psy.properties[cm->charger_psy.num_properties] =