cfg80211: stop critical protocol session upon disconnect event
When user-space has started a critical protocol session and a disconnect
event occurs, the rdev::crit_prot_nlportid remains set. This caused a
subsequent NL80211_CMD_CRIT_PROTO_START to fail (-EBUSY). Fix this by
clearing the rdev attribute and call .crit_proto_stop() callback upon
disconnect event.
Reviewed-by: Hante Meuleman <meuleman@broadcom.com>
Reviewed-by: Pieter-Paul Giesberts <pieterpg@broadcom.com>
Signed-off-by: Arend van Spriel <arend@broadcom.com>
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
diff --git a/net/wireless/sme.c b/net/wireless/sme.c
index 8020b5b..d49ed76 100644
--- a/net/wireless/sme.c
+++ b/net/wireless/sme.c
@@ -917,6 +917,12 @@
nl80211_send_disconnected(rdev, dev, reason, ie, ie_len, from_ap);
+ /* stop critical protocol if supported */
+ if (rdev->ops->crit_proto_stop && rdev->crit_proto_nlportid) {
+ rdev->crit_proto_nlportid = 0;
+ rdev_crit_proto_stop(rdev, wdev);
+ }
+
/*
* Delete all the keys ... pairwise keys can't really
* exist any more anyway, but default keys might.